Line 101: | Line 101: | ||
== CRTs Used in the 517 == | == CRTs Used in the 517 == | ||
517 units with serial numbers 101 through 925 use the DuMont 5XP CRT. | 517 units with serial numbers 101 through 925 use the [[5XP|DuMont 5XP CRT]]. | ||
Later units use a Tek-made CRT, the T517PxH/T54PxH, where "x" designates | Later units use a Tek-made CRT, the T517PxH/T54PxH, where "x" designates | ||
the [[phosphor]] type: 1, 2, 7, 11, or 16. The 5XP has three anode connections | the [[phosphor]] type: 1, 2, 7, 11, or 16. The 5XP used [[multi-band acceleration]] | ||
6.6 kV, 13.3 kV, and 20 kV. The Tek-made CRT has just one anode connection, 20 kV, | and has three anode connections, at 6.6 kV, 13.3 kV, and 20 kV. | ||
The Tek-made CRT has just one anode connection, 20 kV, | |||
and has 15 V/cm sensitivity at 24 kV total acceleration voltage. | and has 15 V/cm sensitivity at 24 kV total acceleration voltage. | ||