The PS501 and PS501-2 have coarse/fine potentiometers for setting the variable output voltage.  
The PS501 and PS501-2 have coarse/fine potentiometers for setting the variable output voltage.  


The PS501-2 additionally features an analog meter to monitor voltage or current.
The '''PS501-2''' additionally features an analog meter to monitor voltage or current.


The '''PS501-1''' has a 0-10/10-20 V switch and a 10-turn pot with mechanical voltage readout.
The '''PS501-1''' has a 0-10/10-20 V switch and a 10-turn pot with mechanical voltage readout.
Line 13: Line 13:
All versions have a 0-400 mA current limiting pot and an output switch.
All versions have a 0-400 mA current limiting pot and an output switch.


Of the PS501-1 two special modified versions do exist:
Two special modified versions of the PS501-1 exist:


PS501-1 MOD 730E is a modified version to power the strain gage adapter [[015-0169-00]].
'''PS501-1 MOD 730E''' is a modified version to power the strain gage adapter [[015-0169-00]].
The strain gage adapter was initially powered by the [[3A10]] differential plug in for the [[561]] or [[564]] oscilloscopes.
The strain gage adapter was initially powered by the [[3A10]] differential plug in for the [[561]] or [[564]] oscilloscopes.
When the production of this oscilloscope series was terminated, the modified PS501-1 MOD 730E
When the production of this oscilloscope series was terminated, the modified PS501-1 MOD 730E
became available as a replacement power supply.
became available as a replacement power supply.


PS501-1 MOD 730F is a modified version to provide power for the Rotational Function Generator [[015-0108-00]]
'''PS501-1 MOD 730F''' is a modified version to provide power for the [[015-0108-00]] Rotational Function Generator (RFG)  
(RFG) and to condition its output signals to be connected to the modified 7B53A MOD FB time base.
and to condition its output signals to be connected to the modified [[7B53A]] MOD FB time base.
Initially the [[3A74]] MOD 730A vertical amplifier and [[2B67]] MOD 730A time base were used in a 561 or 564
 
oscilloscope in the Tektronix Engine Analyzer System. When the production of this oscilloscope series
The [[3A74]] MOD 730A vertical amplifier and [[2B67]] MOD 730A time base were originally used in a [[561]] or [[564]]
oscilloscope as part of the Tektronix [[Engine Analyzer]] System. When the production of this oscilloscope series
was terminated, the modified PS501-1 MOD 730F became available as a functional replacement for generating
was terminated, the modified PS501-1 MOD 730F became available as a functional replacement for generating
the horizontal signal for the xy display.
the horizontal signal for the X-Y display.