39,594
edits
(New page: * [http://w140.com/kurt/tektronix_p6008.pdf Tektronix P6008 Manual (PDF)]) |
No edit summary |
||
(19 intermediate revisions by 5 users not shown) | |||
Line 1: | Line 1: | ||
* [ | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=P6008 | |||
|summary=Passive 66 MHz, x10 probe | |||
|image=Tek P6008 early version.jpg | |||
|caption=Early P6008 | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:070-0362-01.pdf|Tektronix P6008 Manual, 1963]] (OCR) | |||
* [[Media:070-1173-00.pdf|Tektronix P6008 Environmental Probe Manual, 1971]] | |||
}} | |||
There are two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe. | |||
Each was fitted with a BNC connector with no readout encoding pin. | |||
===010-0130-00=== | |||
The '''early (1963) P6008 Probe (010-130 & 010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs. | |||
It came with a 3.5 foot gray cable. | |||
Like the other members of the [[6-32_probes|monolithic probe family]], the early P6008 was rated for temperatures up to 75 °C. | |||
{{BeginSpecs}} | |||
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | |||
{{Spec | Maximum Voltage | 600 V DC or AC p-p, derated above 20 MHz }} | |||
{{Spec | Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) }} | |||
{{Spec | Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) }} | |||
{{Spec | Input capacitance | ~7 pF }} | |||
{{EndSpecs}} | |||
===010-0130-01=== | |||
The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. | |||
It came with a 6 foot white cable. | |||
This later version of the P6008 was rated for temperatures up to 150 °C for the probe and cable and up to 55 °C for the compensation box. | |||
{{BeginSpecs}} | |||
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | |||
{{Spec | Maximum Voltage | 600 V, DC + peak AC, derated with frequency }} | |||
{{Spec | Compensation range | 15 pF to 55 pF }} | |||
{{Spec | Bandwidth | 100 MHz w/15 pF scope inputs }} | |||
{{Spec | Input capacitance | 10-14 pF, depending on scope input capacitance }} | |||
{{EndSpecs}} | |||
==Pictures== | |||
'''Early P6008''' | |||
<gallery> | |||
Tek P6008 early version.jpg | | |||
Tek p6008 1.JPG | | |||
P6008_Int-1.jpeg | Compensating Box Internals | |||
</gallery> | |||
'''1971 version''' | |||
<gallery> | |||
</gallery> | |||
''please add photos'' | |||
[[Category:1 MΩ Oscilloscope probes]] | |||