39,717
edits
No edit summary |
No edit summary |
||
Line 12: | Line 12: | ||
}} | }} | ||
The S-1 | The '''S-1 sampling plug-in head''' provides a single [[GR-874]] 50 Ω input with a 350 ps rise-time. | ||
The S-1 can be used with the 7000 series of sampling plug-ins, as well as the 3S series of sampling units | The S-1 can be used with the 7000 series of [[sampling_oscilloscope|sampling]] plug-ins, as well as the 3S series of sampling units. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Rise time | 350 ps }} | {{Spec | Rise time | 350 ps }} | ||
{{Spec | Bandwidth | 1 GHz }} | {{Spec | Bandwidth | 1 GHz }} | ||
{{Spec | Input amplitude | -1 V to +1 V with ≤1 V<sub>p-p</sub> signals }} | |||
{{Spec | Maximum input | ±5 V<sub>DC</sub> or sine of 10 V<sub>p-p</sub> up to 10 MHz }} | |||
{{Spec | Input impedance | 50 Ω ([[GR-874]]) }} | {{Spec | Input impedance | 50 Ω ([[GR-874]]) }} | ||
{{Spec | Noise | < 2 mV }} | {{Spec | Noise | < 2 mV }} | ||
{{Spec | Features | trigger pickoff for internal triggering }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | ==Links== | ||
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/S-1.html S-1 page @ amplifier.cd] | * [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/S-1.html S-1 page @ amplifier.cd] | ||
==Internals== | |||
The S-1 uses a two-diode sampling gate which has relatively high "kick-out" (leakage of the strobe signal out of the input). | |||
The manual cautions, | |||
<blockquote> | |||
Operating the sampling head without the input connector terminated by a 50 Ω resistor or coaxial | |||
cable will cause a vertical shift of the zero signal baseline by a few millivolts. This is caused by the | |||
strobe kickout signal being reflected from the open input connector, and orriving bock at the sampling | |||
bridge while the bridge is conducting. | |||
</blockquote> | |||
==Pictures== | ==Pictures== |