==Specifications==
{{BeginSpecs}}
* Deflection factor: 0.05 v/cm to 50 V/div DC-coupled, 0.005 v/cm to 50 V/div AC-coupled
{{Spec | Deflection | 5 mV/div (AC) / 50 mV/div (DC) to 20 V/div, 1−2−5, and variable ×2.5 (up to 50 V/div) }}
* Signal inputs: Two signal inputs with more than 60-dB isolation
{{Spec | Inputs | Two signal inputs with more than 60 dB isolation }}
* Step attenuator: 12 calibrated steps are provided: 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, and 20 V/div
{{Spec | Accuracy | Within ±3% of indicated deflection in calibrated position }}
* Accuracy: Within ±3% of indicated deflection in calibrated position
{{Spec | Maximum input | 600 V DC + peak AC }}
* Maximum input voltage: 600 v (dc plus peak ac)
{{Spec | Rise time | 15 ns (18 ns in a [[545]]), 25 ns in 5 mV/div to 20 mV/div ranges }}
* Risetime: 18 nanoseconds in a [[545]]
{{Spec | Bandwidth | DC to 20 MHz in a [[545]] }}
* Frequency response: DC to 20 MHz in a [[545]]
{{EndSpecs}}


Note: Full frequency response is available with deflection sensitivity between 0.05 and 20v/cm.
Note: Full frequency response is available with deflection sensitivity between 50 mV/div and 20 V/div.
In more sensitive positions, the input is DC-coupled and slightly slower.
In more sensitive positions, the input is AC-coupled and slightly slower.