FG502: Difference between revisions

Jump to navigation Jump to search
1,269 bytes added ,  28 November 2018
no edit summary
No edit summary
No edit summary
Line 16: Line 16:
depending on the gating signal width and the generator frequency setting.
depending on the gating signal width and the generator frequency setting.


{{MissingSpecs}}
{{BeginSpecs}}
{{Spec| Frequency | 0.1 Hz to 11 MHz, resolution 10<sup>-4</sup> }}
{{Spec| Frequency stability | ≤0.1% for 1 hour, ≤0.5% for 24 hours (ambient +25 °C ±5 °C)  }}
{{Spec| Frequency accuracy | <3% of full scale from 0.1 Hz to 1 MHz. <5% of full scale from 1 MHz to 10 MHz}}
{{Spec| Output Amplitude | >10 V<sub>p-p</sub> open circuit. >5 V<sub>p-p</sub> into 50 Ω (@ 10 kHz)}}
{{Spec| Output Offset | >±5 V<sub>p-p</sub> open circuit. >±2.5 V<sub>p-p</sub> into 50 Ω }}
{{Spec| Amplitude flatness | Sine, ±1.5 dB ref. to 10 kHz; Square, triangle ±3 dB referenced to sine }}
{{Spec| Sine Distortion | < 0.5% from 10 Hz to 50 kHz. Harmonics >30 dB down at all other frequencies }}
{{Spec| Triangle Symmetry and Linearity | Within 1% from 0.1 Hz to 1.1 MHz, 3% from 1.1 MHz to 11 MHz }}
{{Spec| Risetime (Square/Pulse) | <20 ns }}
{{Spec| VCF | 10 V signal shifts frequency >1000:1  }}
{{Spec| Ext. Gate | 0 to >+2 V, not to exceed +15 V }}
{{Spec| Trigger Output | >5 V open circuit, >2.5 V into 50 Ω }}
{{Spec| Functions |
* Sine
* Square
* Triangle
* +Ramp, −Ramp
* +Pulse, −Pulse
}}
{{EndSpecs}}
 
==Rear Interface==
* Output: A28 (GND A27)
* Trigger Output: B27 (GND B28)
* Gate In: B24 (GND B25)
* VCF In: B21 (GND B22)


==Links==
==Links==

Navigation menu