{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | | ||
title=Tektronix TDS5032 | | title=Tektronix TDS5032 | | ||
summary=350 MHz 2- | summary=Digital Storage 350 MHz 2-channel scope | | ||
image= TDS5032_Waveform_image.jpg | | image= TDS5032_Waveform_image.jpg | | ||
caption=Tektronix TDS5032 | | caption=Tektronix TDS5032 | | ||
introduced= | introduced=? | | ||
discontinued= | discontinued=? | | ||
manuals= | manuals= | ||
* [[Media:55W_14869_15_TDS5000_Series_DPO_Datasheet.pdf| TDS 5000 Series DPO Datasheet]] (743 KB, PDF) | * [[Media: 55W_14869_15_TDS5000_Series_DPO_Datasheet.pdf| TDS 5000 Series DPO Datasheet]] (743 KB, PDF) | ||
* [[Media:071-0876-02_TDS5000_Series_DPO_User_Manual.pdf| TDS5000 Series DPO User Manual]] (5.9 MB, PDF) | * [[Media: 071-0876-02_TDS5000_Series_DPO_User_Manual.pdf| TDS5000 Series DPO User Manual]] (5.9 MB, PDF) | ||
* [[Media:071-1003-00_TDS5104,_TDS5054,_TDS5052_Read_This_First_Manual.pdf| TDS5000 Read This First Manual]] (1.1 MB, PDF) | * [[Media: 071-1003-00_TDS5104,_TDS5054,_TDS5052_Read_This_First_Manual.pdf| TDS5000 Read This First Manual]] (1.1 MB, PDF) | ||
* [[Media:071-1004-02_TDS5000_Series_DPO_Service_Manual.pdf| TDS5000 Series DPO Service Manual]] (3.6 MB, PDF) | * [[Media: 071-1004-02_TDS5000_Series_DPO_Service_Manual.pdf| TDS5000 Series DPO Service Manual]] (3.6 MB, PDF) | ||
* [[Media:071-1316-00_TDS5032_&_TDS5034_Supplement_Manual.pdf| TDS5032 & TDS5034 Supplement Manual]] (144 KB, PDF) | * [[Media: 071-1316-00_TDS5032_&_TDS5034_Supplement_Manual.pdf| TDS5032 & TDS5034 Supplement Manual]] (144 KB, PDF) | ||
}} | }} | ||
The '''Tektronix | The '''Tektronix TDS3052''' is a two-channel, 350 MHz, 5 GS/s digital phosphor oscilloscope with a 10.4 in. LCD active-matrix color display. This series of scopes combines 100,000 wfms/s continuous waveform capture rate and real-time intensity grading so you can see the problem and solve it. An optional touch screen was available for all models but was standard on the TDS5054B and TDS5104B. The operating system is Windows 2000. | ||
Besides the channel inputs, the AUX IN (auxiliary trigger), and Floppy drive, the | Besides the channel inputs, the AUX IN (auxiliary trigger), and Floppy drive, the Left Side panel has two USB ports, two PS-2 ports (Keyboard, Mouse), two VGA connectors, one Parallel port, GPIB, RJ-45, Serial port, line out, line in, and microphone in, and a CD-ROM drive (Opt 16 replaces it with a CD-RW drive), and the Rear panel has a EXT REF (time base reference input), AUX OUT (auxiliary trigger pulse output), and SIGNAL OUT (buffered CH 3 signal on the TDS5054 and TDS5104 only). | ||
Applications Modes available are FastAcq Acquisition (optimizes the instrument for analysis of dynamic signals and capture of infrequent events), Sample, Peak Detect (captures narrow glitches <1 ns at all real-time sample rates), Averaging (from 2 to 10,000 waveforms included in average), Envelope (from 2 to 10,000 waveforms included in min-max envelope), Hi-Res (real-time boxcar averaging reduces random noise and increases resolution), Waveform Database (accumulates a waveform database that provides a three-dimensional array of amplitude, time, and counts), and FastFrame Acquisition (acquisition memory divided into segments, maximum trigger rate >100,000 waveforms per second). | Applications Modes available are FastAcq Acquisition (optimizes the instrument for analysis of dynamic signals and capture of infrequent events), Sample, Peak Detect (captures narrow glitches <1 ns at all real-time sample rates), Averaging (from 2 to 10,000 waveforms included in average), Envelope (from 2 to 10,000 waveforms included in min-max envelope), Hi-Res (real-time boxcar averaging reduces random noise and increases resolution), Waveform Database (accumulates a waveform database that provides a three-dimensional array of amplitude, time, and counts), and FastFrame Acquisition (acquisition memory divided into segments, maximum trigger rate >100,000 waveforms per second). | ||
Line 30: | Line 30: | ||
Std mem: 400 k (1 ch), 200 k (2 ch); Opt 1M mem: 2 M (1 ch), 1 M (2 ch); Opt 2M mem: 8 M (1 ch), 4 M (2 ch) }} | Std mem: 400 k (1 ch), 200 k (2 ch); Opt 1M mem: 2 M (1 ch), 1 M (2 ch); Opt 2M mem: 8 M (1 ch), 4 M (2 ch) }} | ||
{{Spec | Waveform Measurements| Arithmetic: add, subtract, multiply, and divide waveforms;, Fast Fourier Transform (FFT): Magnitude; Vertical Units: Magnitude, Linear, dB, dBm; Window Functions: Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential; OPTIONAL Math: Algebraic Expressions: Extensive algebraic expressions including waveforms, scalars, and results of parametric measurements; Calculus: Integrate, differentiate; Frequency Domain Functions: Spectral magnitude and phase, real and imaginary spectra; Additional Vertical Units: Phase, degrees, radians }} | {{Spec | Waveform Measurements| Arithmetic: add, subtract, multiply, and divide waveforms;, Fast Fourier Transform (FFT): Magnitude; Vertical Units: Magnitude, Linear, dB, dBm; Window Functions: Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential; OPTIONAL Math: Algebraic Expressions: Extensive algebraic expressions including waveforms, scalars, and results of parametric measurements; Calculus: Integrate, differentiate; Frequency Domain Functions: Spectral magnitude and phase, real and imaginary spectra; Additional Vertical Units: Phase, degrees, radians }} | ||
{{Spec | | |||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
TDS3052_Waveform_image.jpg | |||
TDS3052_2.jpg | |||
TDS3052_3.jpg | |||
TDS3052_4.jpg | |||
TDS3052_5.jpg | |||
</gallery> | </gallery> | ||
[[Category:TDS5000 series scopes]] | [[Category:TDS5000 series scopes]] |