The '''Tektronix P80''' is | The '''Tektronix P80''' is an active probe that works only with the [[80|Type 80]] plug-in for the [[581]] and [[585]] oscilloscopes. | ||
{{ | The P80 and contains a [[6688|6688 (E180F) miniature RF pentode]], which functions as a phase splitter providing 93 Ω differential outputs, not a simple cathode-follower. | ||
{{BeginSpecs}} | |||
{{Spec | Rise time | 3.5 ns in combination with [[80|Type 80]] }} | |||
{{Spec | Bandwidth | DC to 100 MHz (from 25 Ω source) in combination with [[80|Type 80]] }} | |||
{{Spec | Deflection | 0.1 V/Div (fixed) without optional attenuators; 0.2/0.4/0.5/1/2/5/10/20/50/100/200/500/1000 V/Div with attenuators }} | |||
{{Spec | Input impedance | 100 kΩ // <14 pF (including capacitive coupler, without attenuators) }} | |||
{{Spec | Input voltage | max. 150 V<sub>DC</sub> in AC position; max. 600 V<sub>DC</sub> with optional capacitive coupler; max. 100 V<sub>DC</sub> when DC coupled (without optional attenuators) }} | |||