The Tektronix 2337 is a ruggedized portable dual-channel, 100 MHz analog scope. An A Ext connector (external signal to the A Trigger Generator) on the front panel, B Ext connector (external signal to the B Trigger Generator) on the front cover, and External Z-Axis connector at the rear round out its connectivity. The front cover also has a | The '''Tektronix 2337''' is a ruggedized portable dual-channel, 100 MHz analog scope. An A Ext connector (external signal to the A Trigger Generator) on the front panel, B Ext connector (external signal to the B Trigger Generator) on the front cover, and External Z-Axis connector at the rear round out its connectivity. The front cover also has a 3½ digit LCD for delta time (disconnects DMM from LCD readout), DC (up to 500 V), RMS AC (up to 350 V), and Ω (up to 20 MΩ) measurements, and B Trigger function. | ||
Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, ALT, CHOP (~275 kHz), ADD, CH 2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep. | Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, ALT, CHOP (~275 kHz), ADD, CH 2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep. |