==Capacitors== | ==Capacitors== | ||
The 465 series scopes use tantalum capacitors. They are known to short out and bring the scope down. | The 465 series scopes use [[tantalum capacitors]]. They are known to short out and bring the scope down. | ||
Typical symptoms will be no trace, or powering on and going off in few seconds due to built in fold-back protection. | Typical symptoms will be no trace, or powering on and going off in few seconds due to built in fold-back protection. |