N: Difference between revisions

Jump to navigation Jump to search
66 bytes added ,  13 August 2021
no edit summary
m (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix | model=)
No edit summary
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar  
manufacturer=Tektronix | model=N|
|manufacturer=Tektronix
summary=Sampling system plug-in|
|series=500-series scopes
image=Type n front2.jpg |  
|type=Type N
caption=Type N front view|
|summary=Sampling system plug-in
introduced=1960 |
|image=Type n front2.jpg  
discontinued=1964 |
|caption=Type N front view
series=[[500-series scopes]]|
|introduced=1960  
manuals=
|discontinued=1964  
|designers=Norm Winningstad
|manuals=
* [http://w140.com/tek_type_n.pdf Tektronix Type N Manual Complete (PDF, OCR)]
* [http://w140.com/tek_type_n.pdf Tektronix Type N Manual Complete (PDF, OCR)]
* [http://bama.edebris.com/manuals/tek/n Tektronix Type N Manual without schematics (BAMA, offline?)]
* [http://bama.edebris.com/manuals/tek/n Tektronix Type N Manual without schematics (BAMA, offline?)]
Line 23: Line 25:
Its risetime is specified to be under 600 picoseconds.   
Its risetime is specified to be under 600 picoseconds.   


Type N was [[introduced in 1960]], superseded by the [[661|Type 661]] Sampling Oscilloscope system a year later,
Type N was [[introduced in 1960]], superseded by the [[661|Type 661]] Sampling Oscilloscope system a year later, and discontinued in 1964.
and discontinued in 1964.


Type N is a complete sampling subsystem, using the 500-series oscilloscope just as a power supply and a display.
Type N is a complete sampling subsystem, using the 500-series oscilloscope just as a power supply and a display.
Line 36: Line 37:


The vertical scale of the Type N is fixed at 10 mV/cm, making Type N one of the few Tektronix plug-ins with fixed vertical gain.
The vertical scale of the Type N is fixed at 10 mV/cm, making Type N one of the few Tektronix plug-ins with fixed vertical gain.
In practice, attenuators such as the [[017-011]] can be placed in the signal path,
In practice, attenuators such as the [[017-011]] can be placed in the signal path, external to the Type N, to achieve the desired sensitivity.
external to the Type N, to achieve the desired sensitivity.
Using an input attenuator also has the effect of attenuating the kick-out pulse seen by the device under test.  
Using an input attenuator also has the effect of attenuating the kick-out pulse seen by the device under test.  


Line 51: Line 51:
For calibration of the timebase of the Type N, the [[013-028|013-028 Timing Standard]] was produced.
For calibration of the timebase of the Type N, the [[013-028|013-028 Timing Standard]] was produced.


==Specifications==
{{BeginSpecs}}
* Rise time: 600 ps   (Bandwidth ~580 MHz)
{{Spec | Rise time | 600 ps }}
* Deflection: 10 mV/Div (fixed)
{{Spec | Bandwidth | ~580 MHz }}
{{Spec | Deflection | 10 mV/Div (fixed) }}
{{EndSpecs}}