6R1A: Difference between revisions

Jump to navigation Jump to search
33 bytes added ,  13 August 2021
no edit summary
No edit summary
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar  
title=Tektronix 6R1A |
|manufacturer=Tektronix
summary=Digital readout plug-in |
|series=567
image=6r1a_front.JPG |
|type=6R1A  
caption=6R1A Front view|
|summary=Digital readout plug-in  
series=[[567]] scope|
|image=6r1a_front.JPG  
introduced=1964 |
|caption=6R1A Front view
discontinued=1972 |
|series=[[567]] scope
manuals=
|introduced=1964  
|discontinued=1972  
|designers=
|manuals=
* [http://bama.edebris.com/download/tek/6r1a/tek%206r1a.v6.pdf Tektronix 6R1A Manual (PDF)]
* [http://bama.edebris.com/download/tek/6r1a/tek%206r1a.v6.pdf Tektronix 6R1A Manual (PDF)]
* [http://w140.com/tek_6r1a_1968_catalog.pdf Tektronix 6R1A in 1968 Catalog (PDF)]
* [http://w140.com/tek_6r1a_1968_catalog.pdf Tektronix 6R1A in 1968 Catalog (PDF)]
Line 23: Line 26:


The 6R1A differs sightly from the 6R1, mainly in what determines the 0% zone.
The 6R1A differs sightly from the 6R1, mainly in what determines the 0% zone.
In the 6R1, the 0% zone is always the leftmost major division of the
In the 6R1, the 0% zone is always the leftmost major division of the trace.
trace. In the 6R1A, the horizontal position of the 0% zone can be set arbitrarily.   
In the 6R1A, the horizontal position of the 0% zone can be set arbitrarily.   


Internally, the 6R1A differs from the 6R1 in how its functions are implemented.
Internally, the 6R1A differs from the 6R1 in how its functions are implemented.
Line 34: Line 37:
In the 6R1A it is two NPN transistors.
In the 6R1A it is two NPN transistors.


The digital display of the Tektronix 6R1 is composed of four [[Burroughs B5092]] Nixie
The digital display of the Tektronix 6R1 is composed of four [[Burroughs B5092]] Nixie tubes for the digits,  
tubes for the digits, and one  
and one [http://www.tube-tester.com/sites/nixie/data/B-5094/b-5094.htm Burroughs B5094] Nixie tube for the units.
[http://www.tube-tester.com/sites/nixie/data/B-5094/b-5094.htm Burroughs B5094] Nixie tube for the units.


There is an extender plug-in, the [[067-0505-00]], that allows a 6R1 or 6R1A to be operated  
There is an extender plug-in, the [[067-0505-00]], that allows a 6R1 or 6R1A to be operated outside the plug-in bay of the 567 for maintenance purposes.   
outside the plug-in bay of the 567 for maintenance purposes.   
There are extension cards, the 012-067 and 012-068 (shown below), that allow the circuit cards in the 6R1 to be accessed for maintenance while the instrument is powered up.
There are extension cards, the 012-067 and 012-068 (shown below),  
that allow the circuit cards in the 6R1 to be accessed for maintenance while the instrument is powered up.


==Specifications==
==Specifications==

Navigation menu