5T1A: Difference between revisions

Jump to navigation Jump to search
3 bytes added ,  13 August 2021
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar  
title=Tektronix 5T1A |
|manufacturer=Tektronix
summary=Timing plugin |
|series=661
image=5t1a front.jpg |
|type=5T1A  
caption=5T1A front |
|summary=Timing plugin  
series=[[661|661 Sampling Scope]] |
|image=5t1a front.jpg  
introduced=1963 |
|caption=5T1A front  
discontinued=(?) |
|introduced=1963  
manuals=
|discontinued=(?)  
|designers=
|manuals=
* [[Media:070-387.pdf|Tektronix 5T1A Manual (PDF)]]
* [[Media:070-387.pdf|Tektronix 5T1A Manual (PDF)]]
* [http://w140.com/tek_fcp/tek_type_5t1a_factory_cal_proc.pdf Tektronix 5T1A Field Recalibration Procedure (PDF)]
* [http://w140.com/tek_fcp/tek_type_5t1a_factory_cal_proc.pdf Tektronix 5T1A Field Recalibration Procedure (PDF)]
Line 14: Line 16:
* [[Media:Tek 5t1a cal outline.pdf|Tektronix 5T1A Calibration Outline (PDF, OCR)]]
* [[Media:Tek 5t1a cal outline.pdf|Tektronix 5T1A Calibration Outline (PDF, OCR)]]
}}
}}
The '''Tektronix 5T1A''' is a timing plug-in [[introduced in 1963]] for the [[661]]  
The '''Tektronix 5T1A''' is a timing plug-in [[introduced in 1963]] for the [[661]] [[sampling oscilloscope]].   
[[sampling oscilloscope]].   


It is an improved version of the [[5T1]].  The job of the 5T1A is to produce three signals:
It is an improved version of the [[5T1]].  The job of the 5T1A is to produce three signals the sampling pulse, the horizontal sweep, and the blanking signal.
the sampling pulse, the horizontal sweep, and the blanking signal.
The input to the 5T1A is a trigger signal. The trigger can arrive from any of four sources:
The input to the 5T1A is a trigger signal. The trigger can arrive
from any of four sources:
* internally from the trigger pick-off in a [[4S1]] or [[4S2A]] plug-in
* internally from the trigger pick-off in a [[4S1]] or [[4S2A]] plug-in
* externally via a [[GR-874 connector]] on the front panel of the 5T1A
* externally via a [[GR-874 connector]] on the front panel of the 5T1A
Line 26: Line 25:
* free-running  
* free-running  
Each of these modes is suited to some measurement scenarios.   
Each of these modes is suited to some measurement scenarios.   
In the case of internal triggering, the signal goes from the trigger pick-off
In the case of internal triggering, the signal goes from the trigger pick-off in the 4S1 to a coaxial interconnect that passes through the 661, connecting the sampling unit to the timing unit.
in the 4S1 to a coaxial interconnect that passes
through the 661, connecting the sampling unit to the timing unit.


Triggering in the 5T1A is accomplished using five [[1N3129]] 20 mA [[tunnel diodes]].
Triggering in the 5T1A is accomplished using five [[1N3129]] 20 mA [[tunnel diodes]].