3B3: Difference between revisions

Jump to navigation Jump to search
21 bytes added ,  14 August 2021
m
→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=
m (Add 050-0582-00 documentation)
m (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar |
title=Tektronix 3B3|
manufacturer=Tektronix |series=560-series scopes |type= 3B3|
summary=Time Base|
summary=Time Base|
image=3b3 front.jpg|  
image=3b3 front.jpg|  
Line 6: Line 6:
introduced=1962 |
introduced=1962 |
discontinued=(?) |
discontinued=(?) |
series=[[560-series scopes]]|
designers= |
manuals=
manuals=
* [http://bama.edebris.com/download/tek/3b3/3b3.djvu Tektronix 3B3 Manual (DjVu)]
* [http://bama.edebris.com/download/tek/3b3/3b3.djvu Tektronix 3B3 Manual (DjVu)]
Line 15: Line 15:
* [[Media:050-0582-00-TEK_3B1-3B3-MOD.pdf|050-0582-00 Q114/Q214 Germanium Transistor Replacement]]
* [[Media:050-0582-00-TEK_3B1-3B3-MOD.pdf|050-0582-00 Q114/Q214 Germanium Transistor Replacement]]
}}
}}
The '''Tektronix Type 3B3''' is sweep unit (time base) [[introduced in 1963]], intended  
The '''Tektronix Type 3B3''' is sweep unit (time base) [[introduced in 1963]], intended for use with the [[561|561A]].  
for use with the [[561|561A]]. It works fine in other [[560-series scopes]].
It works fine in other [[560-series scopes]].


It provides a calibrated delay from 500 ns to 10 s after the trigger event, before
It provides a calibrated delay from 500 ns to 10 s after the trigger event, before sweeping.   
sweeping.  Delayed sweep allows the operator to "zoom in" on regions of interest in a waveform.
Delayed sweep allows the operator to "zoom in" on regions of interest in a waveform.


The 3B3 provides an intensified mode that indicates the selected region of interest in the  
The 3B3 provides an intensified mode that indicates the selected region of interest in the delayed sweep by showing the entire waveform with the trace brighter in the selected region.
delayed sweep by showing the entire waveform with the trace brighter in the selected region.


==Specifications==