3T4: Difference between revisions

Jump to navigation Jump to search
21 bytes added ,  14 August 2021
m
clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=
No edit summary
m (clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar |
title=Tektronix 3T4 |
manufacturer=Tektronix |series=560-series scopes |type= 3T4 |
summary=Programmable Sampling Sweep |
summary=Programmable Sampling Sweep |
image=3t4 front.jpg |
image=3t4 front.jpg |
caption=3T4 sweep unit |
caption=3T4 sweep unit |
series=[[560-series scopes]] |
designers= |
introduced=1965 |
introduced=1965 |
discontinued=(?) |
discontinued=(?) |
Line 11: Line 11:
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline (PDF, OCR)]]
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline (PDF, OCR)]]
}}
}}
The '''Tektronix Type 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in
The '''Tektronix Type 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms.  It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope.  It was [[introduced in 1965]].
for [[560-series scopes]] that is remotely programmable, allowing computer-controlled  
measurements of high-speed repetitive waveforms.  It interfaces with a
[[6R1A]] plug-in in a Type [[567]] scope.  It was [[introduced in 1965]].


==Specifications==
==Specifications==
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div.  There is a  
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div.   
10x calibrated horizontal magnification mode that can be selected, providing
There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale.   
100 ps/div horizontal scale.  The maximum trigger frequency is 1 GHz.   
The maximum trigger frequency is 1 GHz.   


The sweep can be controlled by the staircase ramp generator
The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.   
in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent
to the 3T4.   


The remotely programmable functions are
The remotely programmable functions are