In addition, there are two dedicated, 25 V<sub>AC</sub>, 0.5 A transformer windings per slot, floating up to 350 V<sub>peak</sub> with reference to the common ground.. | In addition, there are two dedicated, 25 V<sub>AC</sub>, 0.5 A transformer windings per slot, floating up to 350 V<sub>peak</sub> with reference to the common ground.. | ||
In mainframes that have a "high-power compartment", that slot has a separate 17.5 V<sub>AC</sub> and 11.5 V<sub>DC</sub> section providing 4 A shared between them, and that slot's 25 V windings are rated 1 A each. | In mainframes that have a "[[TM500 high-power compartments|high-power compartment]]", that slot has a separate 17.5 V<sub>AC</sub> and 11.5 V<sub>DC</sub> section (floating v-v the other supplies) providing 4 A shared between them, and that slot's 25 V windings are rated 1 A each. | ||
For each slot, two uncommitted transistors (one NPN and one PNP) are heatsink-mounted in the mainframe. These are available for the module's power regulation circuits and are rated to dissipate 7.5 W each. | For each slot, two uncommitted transistors (one NPN and one PNP) are heatsink-mounted in the mainframe. These are available for the module's power regulation circuits and are rated to dissipate 7.5 W each. |