533: Difference between revisions

Jump to navigation Jump to search
29 bytes added ,  10 October 2021
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
{{Oscilloscope Sidebar |manufacturer=Tektronix |designers= |
{{Oscilloscope Sidebar
series=500-series scopes |
|manufacturer=Tektronix  
model= 533 |
|series=500-series scopes
summary=15 MHz scope |
|model=533
image=Wellenkino 533a.jpg |
|summary=15 MHz scope
caption=Tektronix 533A front |
|image=Wellenkino 533a.jpg
introduced=1958 |
|caption=Tektronix 533A front
discontinued=1973 |
|introduced=1958
|discontinued=1973
|designers=
manuals=
manuals=
* [[Media:070-0258-00.pdf|533/533A Instruction]] (OCR PDF, 30M)
* [[Media:070-0258-00.pdf|533/533A Instruction]] (OCR PDF, 30M)
Line 14: Line 16:
* [[Media:Tek 533a fcp sep 1966.pdf|533A Factory Calibration Procedure, September 1966]]
* [[Media:Tek 533a fcp sep 1966.pdf|533A Factory Calibration Procedure, September 1966]]
}}
}}
The '''Tektronix Type 533''' is a 15 MHz oscilloscope [[introduced in 1958]]
The '''Tektronix Type 533''' is a 15 MHz oscilloscope [[introduced in 1958]] that uses [[letter-series and 1-series plug-ins]].
that uses [[letter-series and 1-series plug-ins]].


It is similar to a [[535]], but without the second, delayed timebase.
It is similar to a [[535]], but without the second, delayed timebase.
Line 23: Line 24:
Later 533A have [[BNC connector]]s.
Later 533A have [[BNC connector]]s.
The standard CRT for the 533 and 533A is the [[T5330|T5330-2]].
The standard CRT for the 533 and 533A is the [[T5330|T5330-2]].
Difference between 533 and 533A is only trigger mode.
The difference between the 533 and 533A is only the trigger mode.


{{BeginSpecs}}
{{BeginSpecs}}
Line 39: Line 40:
{{Spec | Weight| 61.5 lbs / 27.8 kg }}
{{Spec | Weight| 61.5 lbs / 27.8 kg }}
{{EndSpecs}}
{{EndSpecs}}


==Internals==
==Internals==
Line 48: Line 48:


Trigger pickoff is taken after the cathode follower stage in the vertical amplifier.
Trigger pickoff is taken after the cathode follower stage in the vertical amplifier.
There is a 6DJ8 differential trigger pickoff amplifier followed by half of a 6DJ8 a
There is a 6DJ8 differential trigger pickoff amplifier followed by half of a 6DJ8 a cathode follower, buffering the trigger signal.   
cathode follower, buffering the trigger signal.   


The trigger circuit is a [[6DJ8]] trigger amplifier followed by a 6DJ8 Schmitt trigger.
The trigger circuit is a [[6DJ8]] trigger amplifier followed by a 6DJ8 Schmitt trigger.
Triggering can be from the internal pickoff or from an external signal or "line" trigger,
Triggering can be from the internal pickoff or from an external signal, or "line" trigger via a 6.3 V tap on the power transformer.   
from a 6.3 V tap on the power transformer.   


The 533 contains a 53 °C (128 °F) [[thermal cutoff]].
The 533 contains a 53 °C (128 °F) [[thermal cutoff]].
The high voltages for the CRT, +8,650 V and −1,350 V, are generated by a 60 kHz Hartley power oscillator
The high voltages for the CRT, +8,650 V and −1,350 V, are generated by a 60 kHz Hartley power oscillator and five [[5642]] high-voltage rectifier diode tubes.
and five [[5642]] high-voltage rectifier diode tubes.


==Pictures==
==Pictures==
Line 85: Line 82:
</gallery>
</gallery>


 
{{Parts|533}}
{{Parts|533A}}


[[Category:500 series scopes]]
[[Category:500 series scopes]]

Navigation menu