The '''Tektronix 2336''' is a ruggedized portable dual-channel, 100 MHz analog scope. | The '''Tektronix 2336''' is a ruggedized portable dual-channel, 100 MHz analog scope. The front cover contains a 3 ½ digit LCD for delta time measurements and B trigger function. A 150 MHz modification was available. | ||
The '''2336YA''' is reportedly the same with only a Curtis [[elapsed time meter]] added, and two [[P6101]] probes included. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 100 MHz (≥88 MHz at 2 mV/div) }} | {{Spec | Bandwidth | 100 MHz (≥88 MHz at 2 mV/div) }} | ||
{{Spec | Deflection | 5 mV/div to 5 V/div (1−2−5 sequence), ±3%; Variable control can increase sensitivity to at least 2 mV/div}} | {{Spec | Deflection | 5 mV/div to 5 V/div (1−2−5 sequence), ±3%; Variable control can increase sensitivity to at least 2 mV/div}} | ||
{{Spec | Input Impedance | 1 MΩ ±2% // 20 pF ±10%, 2 channels }} | {{Spec | Input Impedance | 1 MΩ ±2% // 20 pF ±10%, 2 channels }} | ||
{{Spec | Maximum Input Voltage| 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }} | {{Spec | Maximum Input Voltage | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }} | ||
{{Spec | Sweep | A Time Base: 0.5 s/div to 50 ns/div, 1−2−5; B Time Base: 50 ms/div to 50 ns/div, 1−2−5; A and B ×10 magnifier extends max sweep to 5 ns/div }} | {{Spec | Sweep | A Time Base: 0.5 s/div to 50 ns/div, 1−2−5; B Time Base: 50 ms/div to 50 ns/div, 1−2−5; A and B ×10 magnifier extends max sweep to 5 ns/div }} | ||
{{Spec | Trigger Source| VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10 }} | {{Spec | Trigger Source | VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10 }} | ||
{{Spec | Trigger Coupling| AC, LF REJ, HF REJ, or DC }} | {{Spec | Trigger Coupling | AC, LF REJ, HF REJ, or DC }} | ||
{{Spec | Probes| Two [[P6108A]] 100 MHz ×10 probes, BNC connector with a readout pin }} | {{Spec | Vertical modes | CH1, ALT, CHOP (~275 kHz), ADD, CH2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz) }} | ||
{{Spec | Power| 40 W max, 90 − 250 V<sub>AC</sub>, 48 − 440 Hz }} | {{Spec | Horizontal modes | A or B Sweep, A/B Alternate, B Delayed, X-Y }} | ||
{{Spec | Extra inputs | A Trigger Ext (front), B Trigger Ext (front), External Z-Axis (rear) | |||
{{Spec | Probes | Two [[P6108A]] 100 MHz ×10 probes, BNC connector with a readout pin }} | |||
{{Spec | Power | 40 W max, 90 − 250 V<sub>AC</sub>, 48 − 440 Hz }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||