{{TM500 | mfg=Tektronix | type=PG501 | function=50 MHz pulse generator | class=pulse generator | image=Tek-pg501-f.jpg | introduced=1972 | discontinued=1993 |
{{TM500 | mfg=Tektronix | type=PG501 | function=50 MHz pulse generator | class=pulse generator | image=Tek-pg501-f.jpg | introduced=1972 | discontinued=1993 |
designers= |manuals=
designers= |manuals=
* [http://w140.com/smb/PG501_SM.pdf Tektronix PG501 Manual (OCR, PDF)]
* [[Media:070-1361-00.pdf|PG501 Instruction Manual]] (OCR)
}}
}}
{{BeginSpecs}}
{{Spec | Outputs            | simultaneous positive and negative output pulses, fixed 5 ns rise/fall times, independently variable amplitudes from 0.5 V to 5 V into 50 Ω }}
{{Spec | Pulse period      | 20 ns to 20 ms calibrated, 1:10 variable to 200 ms, or externally triggered }}
{{Spec | Pulse duration    | 10 ns to 10 ms calibrated, 1:10 variable to 100 ms, external duration, or "locked on" to adjust output voltage }}
{{Spec | Trigger input      | ≥+1 V High, ≤0.1 V low; max. +5 V DC+peak AC; min. 10 ns on/off; triggers duration generator in Ext Trig mode, controls output in Ext Duration mode }}
{{Spec | Pre-trigger output | 8 ns before main output, 1 V into 50 Ω }}
{{EndSpecs}}


==Specifications==
==Rear Interface==
The PG501 provides simultaneous positive and negative 50 MHz output pulses
* 27B, 28A (GND 27A, 28B) – pre-trigger output, 10 ns before main output, 1 V from 27 Ω source impedance
with 5 ns rise and fall times and independently variable amplitudes
* 25A (GND 26A) – averaged amplitude output, internally connected to +out or -out via 27 kΩ/20 nF, or disconnected
from 0.5 V to 5 V into 50 Ω.  Front panel controls provide calibrated decade
* 24B (GND 25B) – available to connect in parallel to front panel Trig/Duration Input (connecting cable to be user-installed)
selection of pulse period from 20 ns to 20 ms, and duration from
10 ns to 10 ms. Uncalibrated pulse period from 20 ns to 0.2 s and
duration from 10 ns to 0.1 s can be obtained with the variable control.
 
The PG501 has a gate input and a 10 ns pre-trigger output.