== Repair Issues== | == Repair Issues== | ||
* Helitrim potentiometers are prone to failure due to cracking plastic axle | * Helitrim potentiometers are prone to failure due to cracking plastic axle. | ||
* (Tantalum) Electolytic capacitors, especially on the output transistors | * (Tantalum) Electolytic capacitors, especially on the output transistors. | ||
* [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_500/Reparatur%20Tektronix%20FG502-1-com.pdf FG502 repair report @ amplifier.cd] (German) | * [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_500/Reparatur%20Tektronix%20FG502-1-com.pdf FG502 repair report @ amplifier.cd] (German) | ||
* [https://www.electronicdesign.com/technologies/test-measurement/article/21137778/the-tektronix-function-generator-teardown The Tektronix Function Generator Teardown] - Paul Rako @ electronicdesign.com | * [https://www.electronicdesign.com/technologies/test-measurement/article/21137778/the-tektronix-function-generator-teardown The Tektronix Function Generator Teardown] - Paul Rako @ electronicdesign.com | ||
* For serial numbers below B050740, some FG502's may not shift Output Frequency 1000:1 with 10V or less as specified. To correct this problem, change R125 from 10 kΩ to 9.41 kΩ. | |||