545: Difference between revisions

74 bytes removed ,  4 March 2022
no edit summary
(Shorting the vertical amp burns out the termination resistors not the delay line. Mod Kit 040-227 for early production,)
No edit summary
Line 12: Line 12:
|manuals=
|manuals=
'''545'''
'''545'''
* [[Media:070-198.pdf|Tektronix 545 Manual]] (PDF)
* [[Media:070-198.pdf|Tektronix 545 Manual]]
* [https://w140.com/535_545_operators_handbook.pdf Tektronix 535 and 545 Operators Handbook] (PDF, OCR)
* [https://w140.com/535_545_operators_handbook.pdf Tektronix 535 and 545 Operators Handbook] (OCR)
* [[Media:tek_545_fcp.pdf|545 Factory Calibration Procedure, September 1959]] (PDF, OCR)
* [[Media:tek_545_fcp.pdf|545 Factory Calibration Procedure, September 1959]] (OCR)
* [https://w140.com/tek_545_calibration_and_maintenance_procedure.pdf Tektronix 545 Calibration and Maintenance Procedure] (PDF)
* [https://w140.com/tek_545_calibration_and_maintenance_procedure.pdf Tektronix 545 Calibration and Maintenance Procedure]
* [[Media:tek_545_calibration_maintenance_proc.pdf|Tektronix 545 Calibration and Maintenance Procedure]] (PDF, OCR, bad-OCR)
* [[Media:tek_545_calibration_maintenance_proc.pdf|Tektronix 545 Calibration and Maintenance Procedure]] (bad-OCR)


'''545A'''
'''545A'''
* [[Media:070-163.pdf|545A Instruction]] (PDF, 20M, OCR)
* [[Media:070-163.pdf|545A Instruction]] (20M, OCR)
* [[Media:tek_545a_fcp_early.pdf|545A Factory Calibration Procedure, January 1961]] (PDF, OCR)
* [[Media:tek_545a_fcp_early.pdf|545A Factory Calibration Procedure, January 1961]] (OCR)
* [[Media:tek_545a_fcp.pdf|545A Factory Calibration Procedure, July 1961]] (PDF, OCR)
* [[Media:tek_545a_fcp.pdf|545A Factory Calibration Procedure, July 1961]] (OCR)


'''545B'''
'''545B'''
* [http://bama.edebris.com/download/tek/545b/545b.djvu Tektronix 545B Manual] (DJVu)
* [https://bama.edebris.com/download/tek/545b/545b.djvu Tektronix 545B Manual] (DJVu)
* [[Media:Tek 545b irb.pdf|Tektronix 545B Instrument Reference Book]] (PDF, OCR)
* [[Media:Tek 545b irb.pdf|Tektronix 545B Instrument Reference Book]] (OCR)
* [[Media:Tek 545b fcp jan 1966.pdf|Tektronix 545B Factory Calibration Procedure, January 1966]] (PDF, needs OCR)
* [[Media:Tek 545b fcp jan 1966.pdf|Tektronix 545B Factory Calibration Procedure, January 1966]] (needs OCR)
* [[Media:Tek 545b fcp tlc up to jan 1969.pdf|Tektronix 545B Factory Calibration Procedure, January 1969]] (PDF, needs OCR)
* [[Media:Tek 545b fcp tlc up to jan 1969.pdf|Tektronix 545B Factory Calibration Procedure, January 1969]] (needs OCR)
* [[Media:Tek 545b eis march 1964.pdf|Tektronix 545B Engineering Instrument Specification]] (PDF)
* [[Media:Tek 545b eis march 1964.pdf|Tektronix 545B Engineering Instrument Specification]]


'''Maintenance and calibration'''
'''Maintenance and calibration'''
* [https://w140.com/tek_balancing_545_vert.pdf Balancing the 540-Series Vertical Amplifier] (PDF, OCR)
* [https://w140.com/tek_balancing_545_vert.pdf Balancing the 540-Series Vertical Amplifier] (OCR)
* [https://w140.com/tek_fcp/tek_adjust_540_vert_delay.pdf How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope] (PDF)
* [https://w140.com/tek_fcp/tek_adjust_540_vert_delay.pdf How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope]
* [https://w140.com/navair_17-20aw-08.pdf Navair 17-20AW-08 Manual, which discusses the 545] (PDF)
* [https://w140.com/navair_17-20aw-08.pdf Navair 17-20AW-08 Manual, which discusses the 545]
}}
}}
The '''Tektronix Type 545''' is a 30 (33) MHz scope that takes [[letter-series and 1-series plug-ins]].  It has two timebases, which allows delayed triggering.   
The '''Tektronix Type 545''' is a 30 (33) MHz scope that takes [[letter-series and 1-series plug-ins]].  It has two timebases, which allows delayed triggering.   
Line 68: Line 68:


{{SpecGroup|545B}}
{{SpecGroup|545B}}
{{Spec | Sweep | 0.1 μs/div to 5 s/div, 1−2−5 }}
{{Spec | Sweep | 0.1 μs/div to 5 s/div, 1−2−5 }}
{{Spec | CRT | T5470-31-2, 10 kV acceleration }}
{{Spec | CRT   | [[T5470]]-31-2, 10 kV acceleration }}
{{Spec | Probes | 2 P6006 probes with BNC connectors }}
{{Spec | Probes | 2 P6006 probes with BNC connectors }}


Line 83: Line 83:


=== 545 and 545A Vertical Path ===
=== 545 and 545A Vertical Path ===
Types 545 and 545A have a six stage differential [[distributed amplifier|distributed vertical amplifier]]
Types 545 and 545A have a six stage differential [[distributed amplifier|distributed vertical amplifier]] made of twelve [[6DK6]] tubes.   
made of twelve [[6DK6]] tubes.   
The vertical amplifier used in the 545A is also used in the [[551]] and [[555]].
The vertical amplifier used in the 545A is also used in the [[551]] and [[555]].
The 545 uses the [[154-098]] CRT.  With the limited CRT technology available at the time, the higher bandwidth of the 541 and 545 came with a tradeoff.   
The 545 uses the [[154-098]] CRT.  With the limited CRT technology available at the time, the higher bandwidth of the 541 and 545 came with a tradeoff.   
The vertical scale is only 4 divisions, 2 above and 2 below the graticule center line.  The lower bandwidth 531/[[Type 533|533]]/535 retained the 6 vertical divisions, as used in most other Tektronix scopes.
The vertical scale is only 4 divisions, 2 above and 2 below the graticule center line.   
The lower bandwidth 531/[[Type 533|533]]/535 retained the 6 vertical divisions, as used in most other Tektronix scopes.
Shorting the outputs of the vertical amplifier to ground can cause expensive damage by burning out the termination resistor network.
Shorting the outputs of the vertical amplifier to ground can cause expensive damage by burning out the termination resistor network.
Starting at Type 545A serial number 29960, there is a 150 mA fuse, F1054, to prevent that failure.  This change was made available for instruments already built, in Modification Kit 040-227.
Starting at Type 545A serial number 29960, there is a 150 mA fuse, F1054, to prevent that failure.   
This change was made available for instruments already built, in Modification Kit 040-227.


=== 545B Vertical Path ===
=== 545B Vertical Path ===