2246: Difference between revisions

Jump to navigation Jump to search
647 bytes added ,  10 October 2023
no edit summary
No edit summary
No edit summary
 
(8 intermediate revisions by 2 users not shown)
Line 11: Line 11:
|manuals=
|manuals=
'''2246'''
'''2246'''
* [[Media:070-6082-00.pdf|Tektronix 2246 Operators Guide]]
* [[Media:070-6083-00.pdf|Tektronix 2246 Operators Manual]]
* [[Media:070-6083-00.pdf|Tektronix 2246 Operators Manual]]
* [[Media:070-7061-00.pdf|Tektronix 2246 Operators Manual SN B100100 and above]] (OCR)
* [[Media:070-7061-00.pdf|Tektronix 2246 Operators Manual SN B100100 and above]] (OCR)
Line 17: Line 18:
'''2246A'''
'''2246A'''
* [[Media:070-6556-01.pdf|Tektronix 2246A Operators Manual]]
* [[Media:070-6556-01.pdf|Tektronix 2246A Operators Manual]]
* [[Media:070-6555-00.pdf|Tektronix 2246A Service Manual]]
{{ROM Images}}
* A16U2408: [[Media:160-5391-00.bin|160-5391-00]] / 160-4084-00
* A16U2519: [[Media:160-5063-11.bin|160-5063-11]] / [[Media:160-5063-00.bin|160-5063-00]] /<br /> [[Media:160-4082-01.bin|160-4082-01]] / 160-4082-00
* A16U2520: [[Media:160-4083-01.bin|160-4083-01]] / 160-4083-00
}}
}}
The '''Tektronix 2246''' is a 100 MHz four-channel analog oscilloscope. Channels 1-2 are fully-functional, whereas 3-4 are limited in both deflection factor and coupling, as they are intended mainly for digital and trigger signals.
The '''Tektronix 2246''' is a 100 MHz four-channel analog oscilloscope [[introduced in 1987]]. It was updated to the [[2246A]] in 1988.


The 2246 includes many of the same features of the 2245A and adds auto tracking SmartCursors which track the selected measurement, trigger level, or ground. There are Labeled Volts Cursors with Ground-Referenced Readings and On-Screen Readouts; Hands-Off Voltmeter Measurements of DC Volts, +Peak and -Peak Volts, and P-P Volts; SmartCursors Integrate Voltage, Time, Frequency, and Phase Measurements, and are available in ALT and B Horizontal Modes.
Channels 1-2 are fully-functional, whereas 3-4 are limited in both deflection factor and coupling, as they are intended mainly for digital and trigger signals.
 
The 2246 includes many of the same features of the [[2245A]] and adds auto-tracking SmartCursors which track the selected measurement, trigger level, or ground. There are Labeled Volts Cursors with Ground-Referenced Readings and On-Screen Readouts; Hands-Off Voltmeter Measurements of DC Volts, +Peak and -Peak Volts, and P-P Volts; SmartCursors Integrate Voltage, Time, Frequency, and Phase Measurements, and are available in ALT and B Horizontal Modes.
 
The input buffer amplifier in the 2246A is the [[165-2232-00]].


{{BeginSpecs}}
{{BeginSpecs}}
Line 46: Line 56:
* 2246A  
* 2246A  


==See Also==
==Links==
* [[067-0557-00]]
* See Also [[067-0557-00]]
{{Documents|Link=2246}}
{{Documents|Link=2246A}}


==Pictures==
==Pictures==
Line 67: Line 79:
2246A(2).jpg
2246A(2).jpg
</gallery>
</gallery>
==Components==
{{Parts|2246}}
{{Parts|2246A}}


[[Category:2246 series scopes]]
[[Category:2246 series scopes]]

Navigation menu