39,731
edits
m (→top: clean up, replaced: manuals= → designers= |manuals=) |
No edit summary |
||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=DC502 | function=550 MHz frequency counter | class=counter | image=Tek dc502 opt1 1.jpg | introduced=1972 | discontinued=1977 | designers= |manuals= | {{TM500 | mfg=Tektronix | type=DC502 | function=550 MHz frequency counter | class=counter | image=Tek dc502 opt1 1.jpg | introduced=1972 | discontinued=1977 | designers= |manuals= | ||
* [[Media:DC502 070-1412-00.pdf|Tektronix DC502 Manual | * [[Media:DC502 070-1412-00.pdf|Tektronix DC502 Manual]] | ||
}} | }} | ||
It measures frequencies from 10 Hz to 550 MHz or totalizes events up to the readout capacity of 10<sup>7</sup> | It measures frequencies from 10 Hz to 550 MHz or totalizes events up to the readout capacity of 10<sup>7</sup>−1 at the maximum rate of 550 MHz. | ||
{{BeginSpecs}} | |||
{{Spec|Resolution|7 digits}} | |||
{{Spec|Frequency range | 10 Hz to 110 MHz (Direct input); 50 MHz to 550 MHz (÷10 input) }} | |||
{{Spec|Sensitivity|300 mV<sub>p-p</sub> or 100 mV<sub>rms</sub> sine (Direct input); 500 mV<sub>p-p</sub> or 170 mV<sub>rms</sub> sine (÷10 input) }} | |||
{{Spec|Input impedance| 1 MΩ (Direct input); 50 Ω (÷10 input) }} | |||
{{Spec|Gate time| 0.01 s, 0.1 s, 1.0 s, or 10 s }} | |||
{{Spec|Stability|1×10<sup>−5</sup> (10 ppm) standard, 5×10<sup>−7</sup> (0.5 ppm) with Opt.01}} | |||
{{Spec|Features| | |||
* 7-digit LED Display, automatic decimal point and leading zero blanking | |||
* manual Start/Stop (Totalize) | |||
* adjustable trigger level on direct input | |||
}} | |||
{{EndSpecs}} | |||
The manual totalizing mode with front panel start stop control is available in both inputs; from the prescale input, 1 displayed count per 10 input events will result. | The manual totalizing mode with front panel start stop control is available in both inputs; from the prescale input, 1 displayed count per 10 input events will result. | ||
LEDs indicate when the gate is armed, and whether displayed numbers are in kHz or MHz, and when register overflow occurs. | LEDs indicate when the gate is armed, and whether displayed numbers are in kHz or MHz, and when register overflow occurs. | ||
The internal clock is 1 MHz. The Opt.05 high stability oscillator runs at 5 MHz with an additional by-5 divider. | |||
==Links== | ==Links== | ||
* [http://www.barrytech.com/tektronix/tektm500/tekdc502.html DC502 @ barrytech.com] | * [http://www.barrytech.com/tektronix/tektm500/tekdc502.html DC502 @ barrytech.com] | ||
==Rear Interface== | |||
{| class="wikitable" | |||
|- | |||
! Connector Pin | |||
! Signal | |||
|- | |||
| 28B || Second decimal point output | |||
|- | |||
| 27B || MHz light output | |||
|- | |||
| 27A || Internal Scan Clock Disable | |||
|- | |||
| 26A || /RESET | |||
|- | |||
| 25B || External Scan Clock input | |||
|- | |||
| 25A || Time Slot Zero | |||
|- | |||
| 24B || Internal Scan Clock output (2 kHz) | |||
|- | |||
| 23B || Overflow | |||
|- | |||
| 22B || MSD output | |||
|- | |||
| 21B || BCD output 2 | |||
|- | |||
| 20B || BCD output 8 | |||
|- | |||
| 20A || BCD output 4 | |||
|- | |||
| 19A || BCD output 1 | |||
|- | |||
| 19B || Data Good | |||
|} | |||
Data is output serially by digit. | |||
==Pictures== | ==Pictures== |