Screen V-sync was very unstable. Root cause: C521 was found installed with incorrect polarity, presumably ex factory (original-looking solder joint). | :'''Symptom:''' Screen V-sync was very unstable, adjustment range insufficient. | ||
High leakage current resulted. Fix: Replace C521. | :'''Root cause:''' C521 (1 μF) in phase detector circuit was found installed with incorrect polarity, presumably ex factory (original-looking solder joint). High leakage current resulted. | ||
:'''Fix:''' Replace C521 (install with correct polarity). | |||