2792: Difference between revisions

Jump to navigation Jump to search
173 bytes removed ,  15 October 2022
no edit summary
No edit summary
No edit summary
 
Line 10: Line 10:
|designers=
|designers=
|manuals=
|manuals=
* Operator’s and Service Manuals needed
* Operator's and Service Manuals needed
* [[Media:tek_2790_series_programming_manual.pdf| Tektronix 2790 Series Programming Manual (PDF)]]
* [[Media:070-8643-00.pdf|Tektronix 2790 Series Programming Manual]]
* [[Media:Tektronix_279X_Catalog_Datasheet.pdf| Tektronix 279X Datasheet (PDF)]]
* [[Media:Tek 2792 schematics.pdf|Tektronix 2792 Schematics]]
* [[Media:Tek 2792 schematics.pdf|Tektronix 2792 Schematics]]
* [[Media:tek_2790_series_programming_manual.pdf|Tektronix 2790 Series Programming Manual]]
* [[Media:Tektronix_279X_Catalog_Datasheet.pdf|Tektronix 279x Datasheet]]
}}
}}
The '''Tektronix 2792''' is a spectrum analyzer with a frequency range of 10 kHz to 21 GHz in coax, to 26.5 GHz with option 04.  The minimum resolution bandwidth is 1 kHz, and provides measurement resolution proportional to the frequency accuracy or span.  In addition to conventional digital storage features, non-volatile memory (NVRAM) stores up to 9 separate waveforms with their readouts and markers, for later recall for additional analysis and comparison.  Also, store up to 10 different front-panel control setups for future recall.  The instrument can selectively count one particular signal out of several that may be present at its input.
The '''Tektronix 2792''' is a spectrum analyzer with a frequency range of 10 kHz to 21 GHz in coax, to 26.5 GHz with option 04.  The minimum resolution bandwidth is 1 kHz, and provides measurement resolution proportional to the frequency accuracy or span.  In addition to conventional digital storage features, non-volatile memory (NVRAM) stores up to 9 separate waveforms with their readouts and markers, for later recall for additional analysis and comparison.  Also, store up to 10 different front-panel control setups for future recall.  The instrument can selectively count one particular signal out of several that may be present at its input.
Line 44: Line 46:
{{Spec | Display Dynamic Range | 80 dB }}
{{Spec | Display Dynamic Range | 80 dB }}
{{Spec | Dynamic Range (Compression to noise) | 110 dBm }}
{{Spec | Dynamic Range (Compression to noise) | 110 dBm }}
{{Spec | Included Accessories |Operator’s Manual; Programmer’s Manual; 6-ft, 50Ω coaxial cable, N-N; 18-inch, 50Ω coaxial cable, BNC-BNC; N male to BNC female adapter; rear connector shield; power cord and spare fuses }}
{{Spec | Weight | 21.3 kg (46 lbs) }}
{{Spec | Weight | 21.3 kg (46 lbs) }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 47 to 63 Hz; 180 – 250 V<sub>AC</sub>, 47 to 63 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 210 W max }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 47 to 63 Hz; 180 – 250 V<sub>AC</sub>, 47 to 63 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 210 W max }}