Neon Lamps: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
[[File:NE-2 lamp.jpg|thumb|right|NE-2 neon lamp]]
'''Neon lamps''' are used for at least three different things in Tek instruments:
'''Neon lamps''' are used for at least three different things in Tek instruments:
# Indicator lamps, e.g., for power, beam position, uncalibrated status, or a decimal point
# Indicator lamps, e.g., for power, beam position, uncalibrated status, or a decimal point
Line 14: Line 15:
If the neon lamps fail, the CRT grid voltage will be affected.
If the neon lamps fail, the CRT grid voltage will be affected.


Another common use is for DC bias shifting, e.g. in 500-series timebase circuits.  In such circuits, a 56 V Zener diode may be a possible replacement for the neon.
Another common use is for DC bias shifting, e.g. in 500-series timebase circuits, or the horizontal output of the [[511]].  In such circuits, a 56 V Zener diode may be a possible replacement for the neon.


[[File:Neons in 545 timebase circuit.jpg|200px]]
545 timebase: [[File:Neons in 545 timebase circuit.jpg|250px|545 timebase]] 511 H output: [[File:511A H amplifier detail.png|250px|511A sweep output]]




Line 42: Line 43:
!Nominal
!Nominal
|-
|-
| NE-2  
| [[NE-2]]
| 150-002
| 150-002, 150-0002-00
|align="center"| 76 (60−90) V   
|align="center"| 76 (60−90) V   
|align="center"| 58 V
|align="center"| 58 V
Line 50: Line 51:
|-
|-
| NE-2V
| NE-2V
| 150-030
| 150-030, 150-0030-00
|align="center"| 76 (60−90) V   
|align="center"| 76 (60−90) V   
|align="center"| 58 (46-78) V
|align="center"| 58 (46-78) V
Line 57: Line 58:
|-
|-
| NE-23
| NE-23
| 150-027
| 150-027, 150-0027-00
|align="center"| 74 (60−90) V   
|align="center"| 74 (60−90) V   
|align="center"| 59 V
|align="center"| 59 V

Navigation menu