{{Plugin Sidebar |
{{Plugin Sidebar  
manufacturer=Tektronix |series=560-series scopes |type= 3L5 |
|manufacturer=Tektronix  
summary=1 MHz Spectrum Analyzer |
|series=560-series scopes  
image=Tek 3L5 front2.jpeg |
|type=3L5  
caption=Tektronix 3L5 Spectrum Analyzer |
|summary=1 MHz Spectrum Analyzer  
designers=  |
|image=Tek 3L5 front2.jpeg  
introduced=1967 |
|caption=Tektronix 3L5 Spectrum Analyzer  
discontinued=(?) |
|introduced=1967
|discontinued=(?)
manuals=
manuals=
* [[Media:070-0630-01.pdf|Tektronix 3L5 Manual (PDF)]]
* [[Media:070-0630-01.pdf|Tektronix 3L5 Manual]]
* [[Media:Tek 3l5 fcp aug 1967.pdf|Tektronix 3L5 Factory Calibration Procedure, August 1967 (PDF)]]
* [[Media:Tek 3l5 fcp aug 1967.pdf|Tektronix 3L5 Factory Calibration Procedure, August 1967]]
}}
}}
The '''Tektronix 3L5''' is a 50 Hz 1 MHz spectrum analyzer plug-in for [[560-series scopes]].  
The '''Tektronix 3L5''' is a 50 Hz - 1 MHz spectrum analyzer plug-in for [[560-series scopes]]. It is very similar to the [[1L5]].
It is very similar to the [[1L5]] and can be used to measure the spectrum of signals.


In conjunction with the [[015-0107-00]] Swept Frequency Converter (tracking generator), the 3L5 can also be used to make scalar frequency response measurements.
In conjunction with the [[015-0107-00]] Swept Frequency Converter (tracking generator), the 3L5 can also be used to make scalar frequency response measurements.
Line 29: Line 28:
===Timebase Support===
===Timebase Support===
3L5 requires a timebase plug-in in the horizontal compartment to operate.  
3L5 requires a timebase plug-in in the horizontal compartment to operate.  
Timebase plug-in units with serial no listed and below require modification [[040-0413-00]] to provide the sweep signal to the 3L5 (To pin 18 of the [[560_Series_plug-in_interface|plug-in connector]]).
 
Timebase plug-in units with serial numbers listed below require modification [[040-0413-00]] to provide the sweep signal to the 3L5 (To pin 18 of the [[560_Series_plug-in_interface|plug-in connector]]).


{| class="wikitable"
{| class="wikitable"
Line 36: Line 36:
! SN#  
! SN#  
|-
|-
| [[2B67]] ||15180
| [[2B67]] || <15180
|-
|-
| [[3B1]]  ||4040
| [[3B1]]  || <4040
|-
|-
| [[3B3]]  ||4270
| [[3B3]]  || <4270
|-
|-
| [[3B4]]  ||740
| [[3B4]]  || <740
|}
|}


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Center Frequency Range | 50 Hz to 990 kHz}}
{{Spec | Center Frequency   | 50 Hz to 990 kHz }}
{{Spec | Dispersion Range | 10 Hz to 100 kHz}}
{{Spec | Dispersion         | 10 Hz to 100 kHz }}
{{Spec | Input Impedance | 1 MΩ // 30 pF }}
{{Spec | Input Impedance     | 1 MΩ // 30 pF }}
{{Spec | Input Voltage | Max. 300 V (DC + peak AC) }}
{{Spec | Input Voltage       | Max. 300 V (DC + peak AC) }}
{{Spec | Vertical Resolution | Video - .1 v/div to 100 v/div, LIN - .001 V to 2V RMS}}
{{Spec | Vertical Resolution | Video - 100 mV/div to 100 V/div, LIN - 1 mV to 2 V<sub>RMS</sub> }}
{{Spec | Internal Cal Signal | 5 kHz ±1%}}
{{Spec | Internal Cal Signal | 5 kHz ±1% }}
{{Spec | First LO Out | ≥1 MHz (Sweep), ≥1 V<sub>p-p</sub> into ≥1 kΩ}}
{{Spec | First LO Out       | ≥1 MHz (Sweep), ≥1 V<sub>p-p</sub> into ≥1 kΩ }}
{{Spec | Recorder Out | 5 mV to 15 mV into 600Ω}}
{{Spec | Recorder Out       | 5 mV to 15 mV into 600 Ω }}
{{Spec | Weight | ≈6 pounds }}
{{Spec | Weight             | 2.7 kg / 6 lbs }}