36,375
edits
No edit summary |
No edit summary |
||
Line 46: | Line 46: | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Options== | ===Options=== | ||
<small> | |||
* Opt. 01: 300 Hz Resolution Bandwidth filter; Phase-lock with span/div ≤20 kHz | * Opt. 01: 300 Hz Resolution Bandwidth filter; Phase-lock with span/div ≤20 kHz | ||
* Opt. 02: Frequency Counter, 1 Hz or 1 kHz, menu selectable | * Opt. 02: Frequency Counter, 1 Hz or 1 kHz, menu selectable | ||
Line 63: | Line 64: | ||
See also the [[2706|2706 preselector]] and [[2707|2707 tracking generator]]. | See also the [[2706|2706 preselector]] and [[2707|2707 tracking generator]]. | ||
</small> | |||
==Connectors== | ===Connectors=== | ||
Front panel: RF INPUT [[N connector]] (50Ω, +20 dBm Max, 100 V DC blocking capacitor); and GEN [[N connector]] (50Ω, 0 to -48 dBm, Opt. 4 Tracking Generator generates a sweep frequency to enable the Spectrum Analyzer to make circuit response measurements, i.e. scalar network analysis). | Front panel: RF INPUT [[N connector]] (50Ω, +20 dBm Max, 100 V DC blocking capacitor); and GEN [[N connector]] (50Ω, 0 to -48 dBm, Opt. 4 Tracking Generator generates a sweep frequency to enable the Spectrum Analyzer to make circuit response measurements, i.e. scalar network analysis). | ||
Rear panel: J101 [[SMA connector]] (Female SMA installed for Opt. 15), J102 EXT TRIG [[BNC connector]] (10 kΩ, 35V (DC + peak AC)), J103 [[DB9 connector]] (Not RS-232 compatible. Accessory connector: Pin 1 Video Input, Pin 2 Ground, Pin 3 Video Output, Pin 6 Sweep Gate, Pin 7 Sweep Output, all others unused), J104 [[GPIB connector]] | Rear panel: J101 [[SMA connector]] (Female SMA installed for Opt. 15), J102 EXT TRIG [[BNC connector]] (10 kΩ, 35V (DC + peak AC)), J103 [[DB9 connector]] (Not RS-232 compatible. Accessory connector: Pin 1 Video Input, Pin 2 Ground, Pin 3 Video Output, Pin 6 Sweep Gate, Pin 7 Sweep Output, all others unused), J104 [[GPIB connector]] | ||
==Originally included accessories== | ===Originally included accessories=== | ||
Operator’s Manual; Power Cord; Front Cover; Adapter 50 Ω N Male to BNC Female, 75 Ω to 50 Ω Minimum Loss Attenuator N Male to BNC Female | Operator’s Manual; Power Cord; Front Cover; Adapter 50 Ω N Male to BNC Female, 75 Ω to 50 Ω Minimum Loss Attenuator N Male to BNC Female | ||
==Links== | |||
{{Documents|Link=2710}} | |||
==Pictures== | ==Pictures== |