R7103: Difference between revisions

Jump to navigation Jump to search
11 bytes removed ,  16 October 2023
no edit summary
(new in 1985 catalog)
No edit summary
 
Line 10: Line 10:
|designers=Val Garuts;Gene Andrews;Hans Springer;John Addis;Wink Gross;Art Metz;Aris Silzars;Conrad Odenthal;Dave Morgan;
|designers=Val Garuts;Gene Andrews;Hans Springer;John Addis;Wink Gross;Art Metz;Aris Silzars;Conrad Odenthal;Dave Morgan;
|manuals=
|manuals=
* [[Media:070-5039-00.pdf|R7103 Service Manual]] (360MB)
* [[Media:070-5039-00.pdf|R7103 Service Manual]]
}}
}}
The '''Tektronix R7103''' is a 1 GHz mainframe, the rack-mount version of the [[7104]].  
The '''Tektronix R7103''' is a 1 GHz mainframe, the rack-mount version of the [[7104]].  
Line 47: Line 47:
|-
|-
!rowspan=2| Mainframe only
!rowspan=2| Mainframe only
! Catalog price
! Catalog Price
|align=right| $22,920
|align=right| $22,920
|align=right| $30,200
|align=right| $30,200
|-
|-
! In 2022 Dollars
! In 2023 Dollars
|align=right| $61,200
|align=right| $65,600
|align=right| $66,400
|align=right| $71,100
|-
|-
!rowspan=2| Mainframe with<br />[[7A29]] and [[7B10]]
!rowspan=2| Mainframe with<br />[[7A29]] and [[7B10]]
! Catalog price
! Catalog Price
|align=right| $28,155
|align=right| $28,155
|align=right| $37,075
|align=right| $37,075
|-
|-
! In 2022 Dollars
! In 2023 Dollars
|align=right| $75,200
|align=right| $80,500
|align=right| $81,600
|align=right| $87,300
|-
|-
|}
|}
Line 96: Line 96:
''"All of the diagnostic equipment, and much of the construction equipment in the tunnel complex were lost as a result of heat damage and radiation contamination. At present, the loss of normally recoverable and reusable equipment is reported at approximately 32 million dollars."''<ref>https://www.osti.gov/servlets/purl/6607938 ''Containment and Safety Review for the  Mighty Oak Nuclear Weapon Effects Test'' (1987)</ref>
''"All of the diagnostic equipment, and much of the construction equipment in the tunnel complex were lost as a result of heat damage and radiation contamination. At present, the loss of normally recoverable and reusable equipment is reported at approximately 32 million dollars."''<ref>https://www.osti.gov/servlets/purl/6607938 ''Containment and Safety Review for the  Mighty Oak Nuclear Weapon Effects Test'' (1987)</ref>
</blockquote>
</blockquote>
($32M in 1986 is almost $84M in 2022 Dollars.)
($32M in 1986 is almost $90M in 2023 dollars.)


<gallery>
<gallery>
Line 108: Line 108:
<references />
<references />


{{CRTs|R7103}}
==Components==
{{Custom ICs|R7103}}
{{Parts|R7103}}
 




[[Category:7000 series non-storage mainframes]]
[[Category:7000 series non-storage mainframes]]
[[Category:Micro-channel plate CRTs]]
[[Category:Micro-channel plate CRTs]]

Navigation menu