P6460: Difference between revisions

133 bytes added ,  7 November 2023
no edit summary
m (Changed "for the TM-5xx" to "used in the TM500" to be consistent with other Wiki pages.)
No edit summary
Line 1: Line 1:
[[File:P6460.JPG|P6460|300px|right]]
{{Probe Sidebar
|manufacturer=Tektronix
|model=P6460
|summary=Data acquisition probe
|for=DAS9200
|image=P6460.JPG
|caption=Tektronix P6460
|introduced=(?)
|discontinued=(?)
|manuals=
* [[Media:070-4345-00.pdf|P6460 Instruction Manual 070-4345-00]] (OCR)
* [[Media:070-4540-00.pdf|P6460 Service manual addendum 070-4540-00]] (P6450, 91A24 and 91AE24 - needs OCR)
* [[Media:Tek p6460 missing first two pages no ocr.pdf|P6460 Instruction Manual, July 1986 Update]] (incomplete, needs OCR)
}}
The '''Tektronix P6460''' Data Acquisition Probe may be used with [[DAS9200]], [[91A24]], [[91AE24]], [[1240D1]], or [[1240D2]] Logic Analyzers. It may also be used with and is required for the [[DP100]] Digital Video Probe plug-in used in the TM500 mainframes.  
The '''Tektronix P6460''' Data Acquisition Probe may be used with [[DAS9200]], [[91A24]], [[91AE24]], [[1240D1]], or [[1240D2]] Logic Analyzers. It may also be used with and is required for the [[DP100]] Digital Video Probe plug-in used in the TM500 mainframes.  


Line 8: Line 21:
{{Spec | Data channel Bandwidth| 100 MHz}}
{{Spec | Data channel Bandwidth| 100 MHz}}
{{Spec | Minimum Pulse Width | 4 ns}}
{{Spec | Minimum Pulse Width | 4 ns}}
{{Spec | Input Signal Level|-40 to +10 V above threshold (+30 V for RS232)}}
{{Spec | Input Signal Level|-40 V to +10 V above threshold (+30 V for RS232)}}
{{Spec | Threshold Voltage| provided from Logic Analyzer}}
{{Spec | Threshold Voltage| provided from Logic Analyzer}}
{{Spec | Input Capacitance| 5 pF}}
{{Spec | Input Capacitance| 5 pF}}
Line 14: Line 27:
{{Spec | Maximum Voltage between any two Inputs| ±60 V}}
{{Spec | Maximum Voltage between any two Inputs| ±60 V}}
{{EndSpecs}}
{{EndSpecs}}
==Instructions==
* [[Media:070-4345-00.pdf | P6460 Instructions incl. diagram and schematics]] (PDF,OCR)
* [[Media:070-4540-00.pdf|Service manual addendum (P6450,91A24 and 91AE24)(PDF, needs OCR)]]
* [[Media:Tek p6460 missing first two pages no ocr.pdf|P6460 Instructions with July 1986 Update (incomplete, PDF, needs OCR)]]


==Links==
==Links==
* [http://www.barrytech.com/tektronix/probes/tekp6460.html P6460 @ barrytech.com]
* [http://www.barrytech.com/tektronix/probes/tekp6460.html P6460 @ barrytech.com]
==Pictures==
==Pictures==
<gallery>
<gallery>