[[File:Raytheon ck512ax 3.jpg|thumb|right|350px|CK512AX Tube]]
{{Vacuum Tube
{{Vacuum Tube
|Type=Pentode
|Type=Pentode
Line 9: Line 10:
|Designers=
|Designers=
}} intended for use as audio or DC amplifier in wearable or portable instruments, "including hearing aids".
}} intended for use as audio or DC amplifier in wearable or portable instruments, "including hearing aids".
{{BeginSpecs}}
{{Spec | Heater | 0.625 V, 20 mA }}
{{Spec | Anode voltage | 15 V (abs max. 25 V) }}
{{Spec | Transconductance | 150 μS }}
{{Spec | Cathode current | 50 μA (abs max. 100 μA) }}
{{Spec | Input capacitance  | 2.3 pF }}
{{Spec | Output capacitance | 1.5 pF }}
{{Spec | Voltage gain | 26 (Ua 15 V, Ra 1 MΩ, Rg2 2.21 MΩ) }}
{{EndSpecs}}


==Used in ==
==Used in ==
* [[123]] amplifier
{{Part usage}}


==Data==
==Data==


* [http://w140.com/CK512AX.pdf Raytheon CK512AX Datasheet (PDF)]
* [[Media:Raytheon CK512AX datasheet.pdf|Raytheon CK512AX Datasheet]]
* [https://www.radiomuseum.org/tubes/tube_ck512ax.html CK512AX] @ radiomuseum.org