The FG501 is specified at a max frequency of 1 MHz, while the "A" model is specified at 2 MHz. The FG501 features seven different functions: Sine, Triangle, Square, +Ramp, -Ramp, 50%>duty square, 50%<duty. The Duty cycle of the Ramp and pulses (not square) are determined by the equation 1/2,,f,, where the veriable ,,f,, represents frequency.
The "A" model features only 3 functions: Sine, Triangle, Square. But the other absent functions compensated with a variable symmetry function, effectively allowing the same functionality with only three functions. The "A" model also features an attenuator, not found in the non-"A" model.
{{BeginSpecs}}
{{BeginSpecs}}
{{SpecGroup | FG501 }}
{{SpecGroup | FG501 }}
{{Spec | Frequency | 0.01 Hz to 1 MHz in decade steps }}
{{Spec | Frequency | 0.01 Hz to 1 MHz in decade steps}}
{{Spec | Output | Max. 20 V<sub>p-p</sub> into high impedance, 10 V into 50 Ω (SN < B130000: 15/7.5 V)}}
{{Spec | Output | Max. 20 V<sub>p-p</sub> into high impedance, 10 V into 50 Ω (SN < B130000: 15/7.5 V)}}
{{Spec | Offset | Max. ±7.5 V<sub>p-p</sub> into high impedance, 5 V into 50 Ω (SN < B130000: 5/2.5 V }}
{{Spec | Offset | Max. ±7.5 V<sub>p-p</sub> into high impedance, 5 V into 50 Ω (SN < B130000: 5/2.5 V }}