Search results

Jump to navigation Jump to search
  • |summary=Portable 150/250/350 MHz 4-ch scope ...50 MHz portable oscilloscope. The '''2445A''' and '''2455A''' are 150 and 250 MHz versions. CRT is the [[154-0850-01]]. ...
    4 KB (538 words) - 04:47, 11 March 2024
  • During this repair, I found these parts defective. The repairs were much more than a non-functional display and some of the components bel In the course of the repairs, I found these components bad in the unit. ...
    4 KB (574 words) - 07:27, 22 April 2024
  • {{Spec | Power | 90-250 V}} ...switches have a tendency to become very "bouncy". See the [[1230/Repairs|"Repairs" tab]]. ...
    3 KB (378 words) - 11:44, 30 March 2024
  • |summary=Portable 200/250/400 MHz 4-ch scope The '''2445B''' and '''2455B''' are 200 and 250 MHz versions.<br /> ...
    7 KB (919 words) - 17:59, 22 January 2024
  • {{Spec | Power | 90-250 V}} The keypad switches have a tendency to become very "bouncy". See the page "repairs" tab for details. ...
    4 KB (541 words) - 06:27, 17 September 2023
  • {{Spec | Power| 90 − 250 V<sub>AC</sub>, 48 − 445 Hz; 100 W max. }} * [[224x PSU Repairs|2245 Power Supply Repair Information]] ...
    4 KB (509 words) - 02:15, 28 April 2024
  • {{Spec | Record Length (1M Option)| 500 K points on 1 channel; 250 k points on 2 channels ; 130 k points on 3 or 4 channels }} ...om 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel. ...
    10 KB (1,505 words) - 23:16, 1 March 2023
  • {{Spec | Record Length (1M Option)| 500 K points on 1 channel; 250 k points on 2 channels ; 130 k points on 3 or 4 channels }} See the [[TDS794D/Repairs|Repairs page]] regarding HDD/FDD replacements. ...
    7 KB (1,075 words) - 07:45, 6 December 2023
  • TYPE 576 Repairs (Components replaced) ...y Board. Could these be related to other previously discussed problems or repairs? ...
    7 KB (1,185 words) - 13:10, 17 May 2020
  • ...p Option| 250 Hz to 222.25 kHz by digitally combining three decade sweeps (250 Hz—2.25 kHz, 2.25 kHz—22.25 kHz, 22.25 kHz—222.25 kHz), 2.5 s sweep t For internal pictures see the [[7L5/Repairs|repair section]]. ...
    9 KB (1,249 words) - 01:56, 15 March 2024
  • {{Spec | Record Length (1M Option)| 500 K points on 1 channel; 250 k points on 2 channels ; 130 k points on 3 or 4 channels }} See the [[TDS794D/Repairs|Repairs page]] regarding HDD/FDD replacements. ...
    10 KB (1,453 words) - 07:46, 6 December 2023
  • * 1M Option – 500 K points on 1 channel; 250 k points on 2 channels ; 130 k points on 3 or 4 channels See the [[TDS794D/Repairs|Repairs page]] regarding HDD/FDD replacements. ...
    10 KB (1,463 words) - 07:44, 6 December 2023
  • ...ng [[GPIB]], [[RS-232]], or Centronics ports, also compatible with Zip 100/250 disk drives}} See the [[TDS794D/Repairs|Repairs page]] regarding HDD/FDD replacements. ...
    10 KB (1,470 words) - 07:43, 6 December 2023
  • {{Spec | Record Length (1M Option)| 500 K points on 1 channel; 250 k points on 2 channels ; 130 k points on 3 or 4 channels }} ...om 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel. ...
    18 KB (2,715 words) - 07:45, 6 December 2023
  • ...ts]], [[Patents|1,600+ patents]], [[Components|700+ components]], [[People|250+ key people]], and more.</p> *[[250]] ...
    44 KB (4,373 words) - 06:56, 25 April 2024