P6045: Difference between revisions
Jump to navigation
Jump to search
m (-) |
m (Text replacement - "Category:Active Oscilloscope Probes" to "Category:Active oscilloscope probes") |
||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
The '''Tektronix P6045'''is a 230 MHz FET probe. | [[File:p6045 box.jpg|thumb|right|350px]] | ||
The '''Tektronix P6045''' is a 230 MHz FET probe. | |||
The signal amplitude range is | The signal amplitude range is 500 mV. | ||
The offset can be set to any voltage from - | |||
The offset can be set to any voltage from -1 V to to 1 V. Attenuator heads can be | |||
placed on the tip of the P6045, reducing the capacitance, increasing the signal | placed on the tip of the P6045, reducing the capacitance, increasing the signal | ||
amplitude range, and of course reducing the sensitivity. | amplitude range, and of course reducing the sensitivity. | ||
The P6045 requires a ±12.5 V supply from a [[015-0073-00]] or a [[454]]/[[454A]] scope. | |||
==Manuals== | |||
* [http://w140.com/TekP6045.pdf Tektronix P6045 Manual (PDF)] | * [http://w140.com/TekP6045.pdf Tektronix P6045 Manual (PDF)] | ||
==Links== | |||
* [http://www.barrytech.com/tektronix/probes/tekp6045.html P6045] @ barrytech.com | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek p6045 small.png | schematic diagram | |||
Tek 015-0073-00 output connector.png | power connector | |||
</gallery> | </gallery> | ||
[[Category:Active oscilloscope probes]] | |||
[[Category:Active |
Revision as of 09:36, 2 November 2019
The Tektronix P6045 is a 230 MHz FET probe.
The signal amplitude range is 500 mV.
The offset can be set to any voltage from -1 V to to 1 V. Attenuator heads can be placed on the tip of the P6045, reducing the capacitance, increasing the signal amplitude range, and of course reducing the sensitivity.
The P6045 requires a ±12.5 V supply from a 015-0073-00 or a 454/454A scope.
Manuals
Links
- P6045 @ barrytech.com
Pictures
-
schematic diagram
-
power connector