==Wavy trace ==
==Wavy trace ==
:'''Symptom:''' Wavy trace
:'''Symptom:''' Wavy trace
:'''Root cause:''' C786 (100µF 25V) has high internal resistor (ESR ~ 20 ohms). +12.6 v regulator ciruit is oscillating
:'''Root cause:''' C786 (100 µF 25 V) has high internal resistance (ESR ~ 20 Ω) causing +12.6 V regulator circuit to oscillate
:'''Solution:''' Replacing of  electrolytic capacitor C786 with new part.
:'''Solution:''' Replace C786 with new part.