11801: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
discontinued=after 1998 | | discontinued=after 1998 | | ||
manuals= | manuals= | ||
* [[Media:070-7041-00.pdf| | ''– 11801 –'' | ||
* [ | * [[Media:070-7041-00.pdf|11801 Service Manual]] (PDF) | ||
* [ | ''– 11801A –'' | ||
* [ | * [[Media:070-8025-00.pdf|11801A Quick Start]] (PDF) | ||
* [[Media:070-8021-00.pdf|11801A User Manual]] (PDF) | |||
* [[Media:070-7720-01.pdf|11801A Command Reference]] (PDF) | |||
* [[Media:070-7738-01.pdf|11801A Programmer Manual]] (PDF) | |||
''– 11801B –'' | |||
* [[Media:070-8783-00.pdf|11801B User Manual]] (PDF) | |||
* [[Media:070-8781-00.pdf|11801B Service Manual]] (PDF) | |||
* [[Media:070-8784-00.pdf|11801B Programmer Manual]] (PDF) | |||
''– 11801C –'' | |||
* [[Media:070-9971-01.pdf|11801C User Manual]] (PDF) | |||
* [[Media:070-9972-02.pdf|11801C Service Manual]] (PDF) | |||
* [[Media:070-9970-00.pdf|11801C Programmer Manual]] (PDF) | |||
''– Additional Information –'' | |||
* [http://www.ko4bb.com/manuals/index.php?dir=Tektronix/Tektronix_-_11801_Digital_Sampling_Oscilloscope Tektronix 11801 documentation at ko4bb.com] | * [http://www.ko4bb.com/manuals/index.php?dir=Tektronix/Tektronix_-_11801_Digital_Sampling_Oscilloscope Tektronix 11801 documentation at ko4bb.com] | ||
* [[Media:Tek 11801 11802 SM11 diagnostics.pdf|Tektronix 11801, 11802, and SM11 Diagnostics (PDF)]] | * [[Media:Tek 11801 11802 SM11 diagnostics.pdf|Tektronix 11801, 11802, and SM11 Diagnostics (PDF)]] | ||
}} | }} | ||
Line 19: | Line 31: | ||
The 11801A update was introduced in 1991, the 11801B in 1994. | The 11801A update was introduced in 1991, the 11801B in 1994. | ||
The [[CSA803]] is effectively a variant of the 11801. | |||
{{BeginSpecs}} | {{BeginSpecs}} |
Revision as of 02:54, 21 January 2021
The Tektronix 11801 is a digital sampling oscilloscope that takes four 11800 series plug-in sampling modules. Input channel capacity can be expanded using the SM-11 Multi-Channel Unit.
The 11801A update was introduced in 1991, the 11801B in 1994.
The CSA803 is effectively a variant of the 11801.
Key Specifications
Vertical Resolution | 8 bits - 25 points/div |
---|---|
Input Sensitivity | 2 to 255 mV/div in 1 mV/div steps |
Record Duration | 10 ps to 50 ms |
Record Length | 512, 1024, 2048, 4096, 5120 samples |
Sample Rate | up to 200 kHz |
Jitter | 1.1 ps RMS + 4 ppm of position (typical) |
Maximum Trigger Input | 1 Vp-p (1x), 10 Vp-p (10x), 2.5 Vp-p prescaler |
Trigger Sensitivity | 50 mV, DC - 4 GHz, AC coupled trigger prescaler to 10 GHz |
Software
- Tekdump screen capture software for Unix written by Steve Tell: Web page / Download
- TSC screen capture portable software written by Joel Koltner
Prices
1990: $23,500 (2018 value: $44,870)
Pictures
-
11801A
-
11801A
-