RSA3408: Difference between revisions
(Created page with "{{Oscilloscope Sidebar | title=Tektronix RSA3408B | summary=Spectrum Analyzer DC to 8 GHz | image= RSA3403B_1.jpg | caption=Tektronix RSA3408B | introduced=(?) | discontinued=...") |
No edit summary |
||
(12 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{ | {{Instrument Sidebar | ||
|class=Spectrum Analyzer | |||
summary=Spectrum Analyzer | |manufacturer=Tektronix | ||
image= | |model=RSA3408B | ||
caption=Tektronix RSA3408B | | |summary=8 GHz Spectrum Analyzer | ||
introduced=(?) | | |image=RSA3408B_1.jpg | ||
discontinued=(?) | | |caption=Tektronix RSA3408B | ||
manuals= | |introduced=(?) | ||
|discontinued=(?) | |||
* [[Media: | |manuals= | ||
* [[Media: 071-2364- | * [[Media:37W_23236_6.pdf|RSA3000B Datasheet]] (OCR) | ||
* [[Media: 071-2366- | * [[Media:071-2364-02.pdf|RSA3408B User Manual]] (OCR) | ||
* [[Media: 075-1028-00 | * [[Media:071-2366-01.pdf|RSA3408B Service Manual]] (OCR) | ||
* [[Media: 077-0111- | * [[Media:075-1028-00.pdf|RSA3000B 119-7548-XX CPU Card Assembly Replacement Instructions]] (OCR) | ||
* [[Media:077-0111-00.pdf|RSA3303B, RSA3308B, & RSA3408B Programmer Manual]] (OCR) | |||
}} | }} | ||
The '''RSA3308B''' is a portable Real-time Spectrum Analyzer (RSA) meant for lab or production line use with a frequency range of DC to 8 GHz is capable of capturing continuous, intermittent, or random signals. With Digital phosphor spectrum processing (DPX) this RSA provides the user the ability to view time-varying RF signals with color-graded displays based on frequency. For offline spectral analysis users can install the [[RSAVu]] Real-Time Spectrum Analyzer Software on their PC and offload '''.iqt''' and '''.tiq''' waveform data files to it. | The '''RSA3308B''' is a portable Real-time Spectrum Analyzer (RSA) meant for lab or production line use with a frequency range of DC to 8 GHz is capable of capturing continuous, intermittent, or random signals. With Digital phosphor spectrum processing (DPX) this RSA provides the user the ability to view time-varying RF signals with color-graded displays based on frequency. For offline spectral analysis users can install the [[RSAVu]] Real-Time Spectrum Analyzer Software on their PC and offload '''.iqt''' and '''.tiq''' waveform data files to it. | ||
Line 21: | Line 21: | ||
This RSA is capable of performing spectrum analysis of power, ACPR, C/N, OBW, EBW, and spurious signals. Analog modulation analysis is possible with AM, PM, FM, ASK, and FSK signals. Additionally, this RSA can perform digital modulation analysis from BPSK to 256QAM (with option 21 of the [[RSAVu]] software), time characteristics analysis including pulse measurements, constellation analysis, EVM analysis, AM/AM and AM/PM distortion analysis, RFID analysis, signal source analysis, and CCDF analysis. | This RSA is capable of performing spectrum analysis of power, ACPR, C/N, OBW, EBW, and spurious signals. Analog modulation analysis is possible with AM, PM, FM, ASK, and FSK signals. Additionally, this RSA can perform digital modulation analysis from BPSK to 256QAM (with option 21 of the [[RSAVu]] software), time characteristics analysis including pulse measurements, constellation analysis, EVM analysis, AM/AM and AM/PM distortion analysis, RFID analysis, signal source analysis, and CCDF analysis. | ||
Front panel inputs/outputs are: RF IN [[N connector]] (50Ω, +30 dBm max); PreAmp Pwr [[ | Front panel inputs/outputs are: RF IN [[N connector]] (50Ω, +30 dBm max); PreAmp Pwr [[LEMO S-series connector]] (Preamp power connector). | ||
Rear panel inputs/outputs: REF OUT/IN [[BNC connector]]s (50Ω); I+/I- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); Q+/Q- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); TRIG OUT/IN [[BNC connector]]s (50Ω); 421 MHz IF OUT [[BNC connector]] (50Ω); | Rear panel inputs/outputs: REF OUT/IN [[BNC connector]]s (50Ω); I+/I- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); Q+/Q- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); TRIG OUT/IN [[BNC connector]]s (50Ω); 421 MHz IF OUT [[BNC connector]] (50Ω); [[GPIB connector]] (IEEE 488.2); DIGITAL IQ OUT: Q OUTPUT LVDS/I OUTPUT LVDS [[MDR Connector]]s (Opt 5 only) ; and US Power Plug (115 V nominal). | ||
Side panel inputs/outputs: LAN [[Ethernet]] connector (10/100BASE-T), [[VGA Connector]], and 2 X [[USB connector]]s (USB 1.1). | Side panel inputs/outputs: LAN [[Ethernet]] connector (10/100BASE-T), [[VGA Connector]], and 2 X [[USB connector]]s (USB 1.1). | ||
Line 36: | Line 36: | ||
{{Spec | Dynamic Range (Spurious Free) | -73 dBc/36 MHz }} | {{Spec | Dynamic Range (Spurious Free) | -73 dBc/36 MHz }} | ||
{{Spec | Reference Level Range | -50 dBm to +30 dBm (1 dB step) (RF); -30 dBm to +20 dBm (5 dB step) (Baseband); -10 dBm to +20 dBm (5 dB step) (IQ Inputs) }} | {{Spec | Reference Level Range | -50 dBm to +30 dBm (1 dB step) (RF); -30 dBm to +20 dBm (5 dB step) (Baseband); -10 dBm to +20 dBm (5 dB step) (IQ Inputs) }} | ||
{{Spec | Resolution Bandwidth per Span (1 Hz to 10 MHz) | Span > 2 GHz | {{Spec | Resolution Bandwidth per Span (1 Hz to 10 MHz) | Span > 2 GHz: 100 kHz min; to Span 100 Hz: 1 Hz min }} | ||
{{Spec | IQ Inputs (Opt 03) | 40 MHz BW Differential }} | {{Spec | IQ Inputs (Opt 03) | 40 MHz BW Differential }} | ||
{{Spec | IF Ouput | Standard, 421 MHz, 40 MHz BW }} | {{Spec | IF Ouput | Standard, 421 MHz, 40 MHz BW }} | ||
Line 43: | Line 43: | ||
{{Spec | Ext Trigger Threshold Levels | -1.5 to +1.5 V settable }} | {{Spec | Ext Trigger Threshold Levels | -1.5 to +1.5 V settable }} | ||
{{Spec | Displayed Average Noise at 1 GHz (Preamp off) | −151 dBm/Hz }} | {{Spec | Displayed Average Noise at 1 GHz (Preamp off) | −151 dBm/Hz }} | ||
{{Spec | Phase Noise at offsets from 1 GHz (dBc/Hz) | {{Spec | Phase Noise at offsets from 1 GHz (dBc/Hz) | 10 kHz: -112, 1 MHz: -135, 10 MHz: -140 }} | ||
{{Spec | Included Accessories | User Manual, Programmer’s Manual (on CD), Power cord, BNC to N Adapter, USB keyboard, USB mouse, and Front Cover }} | {{Spec | Included Accessories | User Manual, Programmer’s Manual (on CD), Power cord, BNC to N Adapter, USB keyboard, USB mouse, and Front Cover }} | ||
{{Spec | Weight (all options) | 20 kg (44 lbs) }} | {{Spec | Weight (all options) | 20 kg (44 lbs) }} | ||
{{Spec | Power & Dissipation (fully loaded) | 90 - | {{Spec | Power & Dissipation (fully loaded) | 90 - 250 V, 47 to 63 Hz, 400 W max; the principal power switch in at the lower left corner of the rear panel, while the front panel power switch allows ON or STANDBY modes }} | ||
{{Spec | Operating Atmospherics | Temperatures: +10 °C to +40 °C; Humidity: 20% to 80% (no condensation); Altitude: Up to 3000 m (9842 ft) }} | {{Spec | Operating Atmospherics | Temperatures: +10 °C to +40 °C; Humidity: 20% to 80% (no condensation); Altitude: Up to 3000 m (9842 ft) }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Line 56: | Line 56: | ||
* Opt. 06: Removable HDD (40 GB) (RSA3400B Models only) | * Opt. 06: Removable HDD (40 GB) (RSA3400B Models only) | ||
* Opt. 28: TD-SCDMA Analysis | * Opt. 28: TD-SCDMA Analysis | ||
==Service Options== | |||
* Opt. CA1: Single Calibration or Functional Verification | |||
* Opt. C3: Calibration Service 3 Years | |||
* Opt. C5: Calibration Service 5 Years | |||
* Opt. D1: Calibration Data Report | |||
* Opt. D3: Calibration Data Report 3 Years (with Opt. C3) | |||
* Opt. D5: Calibration Data Report 5 Years (with Opt. C5) | |||
* Opt. G3: Complete Care 3 Years (includes loaner, scheduled calibration, and more) | |||
* Opt. G5: Complete Care 5 Years (includes loaner, scheduled calibration, and more) | |||
* Opt. R5: Repair Service 5 Years (including warranty) | |||
== Additional Info== | == Additional Info== | ||
Line 70: | Line 81: | ||
</gallery> | </gallery> | ||
[[Category: Spectrum | [[Category:Spectrum analyzers]] |
Latest revision as of 09:26, 13 October 2022
The RSA3308B is a portable Real-time Spectrum Analyzer (RSA) meant for lab or production line use with a frequency range of DC to 8 GHz is capable of capturing continuous, intermittent, or random signals. With Digital phosphor spectrum processing (DPX) this RSA provides the user the ability to view time-varying RF signals with color-graded displays based on frequency. For offline spectral analysis users can install the RSAVu Real-Time Spectrum Analyzer Software on their PC and offload .iqt and .tiq waveform data files to it.
The RSA’s has a 8.4 inch TFT color display, a 40 GB hard drive, and a diskette drive (either a 3.5-inch 2HD (1.44 MB) or 2DD (720 KB)) to save and load data and settings.
This RSA is capable of performing spectrum analysis of power, ACPR, C/N, OBW, EBW, and spurious signals. Analog modulation analysis is possible with AM, PM, FM, ASK, and FSK signals. Additionally, this RSA can perform digital modulation analysis from BPSK to 256QAM (with option 21 of the RSAVu software), time characteristics analysis including pulse measurements, constellation analysis, EVM analysis, AM/AM and AM/PM distortion analysis, RFID analysis, signal source analysis, and CCDF analysis.
Front panel inputs/outputs are: RF IN N connector (50Ω, +30 dBm max); PreAmp Pwr LEMO S-series connector (Preamp power connector).
Rear panel inputs/outputs: REF OUT/IN BNC connectors (50Ω); I+/I- INPUT BNC connectors (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); Q+/Q- INPUT BNC connectors (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); TRIG OUT/IN BNC connectors (50Ω); 421 MHz IF OUT BNC connector (50Ω); GPIB connector (IEEE 488.2); DIGITAL IQ OUT: Q OUTPUT LVDS/I OUTPUT LVDS MDR Connectors (Opt 5 only) ; and US Power Plug (115 V nominal).
Side panel inputs/outputs: LAN Ethernet connector (10/100BASE-T), VGA Connector, and 2 X USB connectors (USB 1.1).
Key Specifications
Frequency Range | DC to 8 GHz |
---|---|
Max Capture BW | 36 MHz |
RF Input impedance | 50 Ω |
Maximum Safe RF Input Power | +30 dBm ±0.2 V (RF Band) ±5 V (Baseband) ±5 V (IQ input), RF Attn ≥10 dB |
Input RF/Baseband Attenuator | 0 dB to 55 dB (5 dB step) |
Input IQ Input Attenuator | 0 dB to 35 dB (5 dB step) |
Dynamic Range (Spurious Free) | -73 dBc/36 MHz |
Reference Level Range | -50 dBm to +30 dBm (1 dB step) (RF); -30 dBm to +20 dBm (5 dB step) (Baseband); -10 dBm to +20 dBm (5 dB step) (IQ Inputs) |
Resolution Bandwidth per Span (1 Hz to 10 MHz) | Span > 2 GHz: 100 kHz min; to Span 100 Hz: 1 Hz min |
IQ Inputs (Opt 03) | 40 MHz BW Differential |
IF Ouput | Standard, 421 MHz, 40 MHz BW |
Minimum Signal Duration for 100% POI | ≤31 µsec |
Trigger Types | Level, Free run, External, and Freq. Mask Trigger (Opt. 02) |
Ext Trigger Threshold Levels | -1.5 to +1.5 V settable |
Displayed Average Noise at 1 GHz (Preamp off) | −151 dBm/Hz |
Phase Noise at offsets from 1 GHz (dBc/Hz) | 10 kHz: -112, 1 MHz: -135, 10 MHz: -140 |
Included Accessories | User Manual, Programmer’s Manual (on CD), Power cord, BNC to N Adapter, USB keyboard, USB mouse, and Front Cover |
Weight (all options) | 20 kg (44 lbs) |
Power & Dissipation (fully loaded) | 90 - 250 V, 47 to 63 Hz, 400 W max; the principal power switch in at the lower left corner of the rear panel, while the front panel power switch allows ON or STANDBY modes |
Operating Atmospherics | Temperatures: +10 °C to +40 °C; Humidity: 20% to 80% (no condensation); Altitude: Up to 3000 m (9842 ft) |
Options (specific to RSA – Not RSAVu software)
- Opt. 02: 65.5 MSample Deep Memory, Frequency Mask Trigger
- Opt. 03: IQ, Differential IQ inputs
- Opt. 05: Digital IQ Output (RSA3400B Models only)
- Opt. 06: Removable HDD (40 GB) (RSA3400B Models only)
- Opt. 28: TD-SCDMA Analysis
Service Options
- Opt. CA1: Single Calibration or Functional Verification
- Opt. C3: Calibration Service 3 Years
- Opt. C5: Calibration Service 5 Years
- Opt. D1: Calibration Data Report
- Opt. D3: Calibration Data Report 3 Years (with Opt. C3)
- Opt. D5: Calibration Data Report 5 Years (with Opt. C5)
- Opt. G3: Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- Opt. G5: Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- Opt. R5: Repair Service 5 Years (including warranty)