DM44: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(24 intermediate revisions by 6 users not shown)
Line 1: Line 1:
The Tektronix DM44 is a digital multimeter module that attaches to the top of the
{{Plugin Sidebar
[[464]], [[465]], [[466]], and [[475]]. It replaced the [[DM40]] and [[DM43]].
|manufacturer=Tektronix  
|series=464
|type=DM44
|summary=DMM top for [[464]]/[[465]]/[[466]]/[[475]]
|image=Tek 475 with dm44.jpg
|caption=DM44 on top of a [[475]] scope
|introduced=1975
|discontinued=(?)
|designers=
|manuals=
* [[Media:070-2036-00.pdf|Tektronix DM44 Manual]]
* [[Media:070-2038-00.pdf|Tektronix 465 and DM44 Operators Manual]]
* [https://w140.com/tek_dm44_description.pdf DM44 Description]


* [http://w140.com/tek_dm44_description.pdf DM44 Description (PDF)]
* [https://hakanh.com/dl/docs/kitinstructions/040-0814-02.pdf 040-0814-02]: Installation of DM44 on [[465]] B052300 - B251074
* [https://hakanh.com/dl/docs/kitinstructions/040-0815-01.pdf 040-0815-01]: Installation of DM44 on [[465]] B251075 & up
* [https://hakanh.com/dl/docs/kitinstructions/040-0944-00.pdf 040-0944-00]: Installation of DM44 on [[465B]]
* [https://hakanh.com/dl/docs/kitinstructions/040-0817-01.pdf 040-0817-01]: Installation of DM44 on [[475]]
}}
The '''Tektronix DM44''' is a 3½-digit digital multimeter module with manual range switching and LED readout that attaches to the top of the [[464]], [[465]], [[466]], and [[475]]. It replaced the [[DM40]] and [[DM43]].


{{BeginSpecs}}
{{Spec | DC V Range            | 200 mV to 1.2 kV in 5 decade steps }}
{{Spec | DC V Accuracy        | 0.1% of reading, ±1 Count }}
{{Spec | DC V Input Resistance | 10 MΩ, Removable internal wire strap to increase input resistance to 1000 MΩ on 200 mV and 2 V Ranges}}
{{Spec | Max. Input            | ±1200 V (DC + peak AC) between positive input and Common input/chassis, ±500 V (DC + peak AC) to Chassis }} 
{{Spec | Resistance Range      | 200 Ω to 20 MΩ in 6 decade steps }}
{{Spec | Resistance Accuracy  | 200 Ω to 2 MΩ, 0.25%, ±1 count; 20 MΩ, 0.30%, ±1 count }}
{{Spec | Temperature Range    | −55 °C to +150 °C (with [[P6430]] Probe) }}
{{EndSpecs}}
==Links==
* [https://lazyelectrons.wordpress.com/2018/02/18/tektronix-475a-dm44-repair/ Lazy Electrons Tektronix 475A & DM44 Repair Page]
* [https://www.youtube.com/watch?v=WPgkVThknYo Tek 475A / DM44 repair] by vintageTek Museum @ YouTube
{{Documents|Link=DM44}}
==Pictures==
<gallery>
<gallery>
Tek 465 with dm44.jpg|465B with DM44
Tek 475 with dm44.jpg|475 with DM44
Tek 466 with dm44.jpg|466 with DM44
Tek 466 with dm44.jpg|466 with DM44
dm44-input.jpg | Inputs (side panel)
DM44_Top.jpg | DM44 Board Top View - Installed in a 475A
DM44_onBench_Side.jpg |DM44 PCB/Module Side view
DM44_onBench_Front.jpg |DM44 PCB/Module Front view
DM44_onBench_Top.jpg | DM44 PCB/Module Top view
DM44_onBench_Under.jpg | DM44 PCB/Module PCB Trace side
DM44_Scope_Cover.jpg | DM44 Install - Cutout in 475A Case
DM44-Circuit01.jpg | DM44 installed in a 475
DM44-Removal01.jpg | DM44 Connectors to detach for removal from 475
DM44-Underside.jpg | Underside of DM44
</gallery>
</gallery>


[[Category:Digital multimeters]]
[[Category:Digital multimeters]]
[[Category:Specifications needed]]
[[Category:Specifications needed]]
[[Category:Image needed]]
[[Category:Manual needed]]
[[Category:Introduced in 1975]]

Latest revision as of 07:01, 12 October 2023

Tektronix DM44
DMM top for 464/465/466/475
DM44 on top of a 475 scope

Compatible with 464

Produced from 1975 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix DM44 is a 3½-digit digital multimeter module with manual range switching and LED readout that attaches to the top of the 464, 465, 466, and 475. It replaced the DM40 and DM43.

Key Specifications

DC V Range 200 mV to 1.2 kV in 5 decade steps
DC V Accuracy 0.1% of reading, ±1 Count
DC V Input Resistance 10 MΩ, Removable internal wire strap to increase input resistance to 1000 MΩ on 200 mV and 2 V Ranges
Max. Input ±1200 V (DC + peak AC) between positive input and Common input/chassis, ±500 V (DC + peak AC) to Chassis
Resistance Range 200 Ω to 20 MΩ in 6 decade steps
Resistance Accuracy 200 Ω to 2 MΩ, 0.25%, ±1 count; 20 MΩ, 0.30%, ±1 count
Temperature Range −55 °C to +150 °C (with P6430 Probe)

Links

Documents Referencing DM44

Document Class Title Authors Year Links
Tekscope 1976 V8 N3.pdf Article Taking the Delay out of Delaying Sweep Measurements Bill Law 1976

Pictures