2336: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
(10 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar| | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
image=Tektronix_2336.jpg | | |series=2000-series scopes | ||
caption=Tektronix 2336 | | |model= 2336 | ||
introduced=1982 | | |image=Tektronix_2336.jpg | ||
discontinued=1991 | | |caption=Tektronix 2336 | ||
summary=Ruggedized 100 MHz dual trace scope | | |introduced=1982 | ||
manuals= | |discontinued=1991 | ||
* [[Media: | |summary=Ruggedized 100 MHz dual trace scope | ||
* [[Media: | |designers= | ||
* [[Media:070- | |manuals= | ||
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] ( | * [[Media:070-4118-00.pdf|Tektronix 2336 Service Manual]] | ||
* [[Media:070-5010-00.pdf|Tektronix 2336 YA Operators Manual 070-5010-00]] | |||
* [[Media:070-5011-00.pdf|Tektronix 2336 YA Service Manual 070-5011-00]] | |||
* [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure]] | |||
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure]] (OCR) | |||
}} | }} | ||
The '''Tektronix 2336''' is a ruggedized portable dual-channel, 100 MHz analog scope. The front cover contains a 3 ½ digit LCD for delta time measurements and B trigger function. A 150 MHz modification was available. | |||
The ''' | The '''2336YA''' is reportedly the same with only a Curtis [[elapsed time meter]] added, and two [[P6101]] probes included. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | {{Spec | Bandwidth | 100 MHz (≥88 MHz at 2 mV/div) }} | ||
{{Spec | Deflection | {{Spec | Deflection | 5 mV/div to 5 V/div (1−2−5 sequence), ±3%; Variable control can increase sensitivity to at least 2 mV/div}} | ||
{{Spec | Input Impedance| 1 MΩ ±2% | {{Spec | Input Impedance | 1 MΩ ±2% // 20 pF ±10%, 2 channels }} | ||
{{Spec | Maximum Input Voltage| 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }} | {{Spec | Maximum Input Voltage | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }} | ||
{{Spec | Sweep | {{Spec | Sweep | A Time Base: 0.5 s/div to 50 ns/div, 1−2−5; B Time Base: 50 ms/div to 50 ns/div, 1−2−5; A and B ×10 magnifier extends max sweep to 5 ns/div }} | ||
{{Spec | Trigger Source| VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10 }} | {{Spec | Trigger Source | VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10 }} | ||
{{Spec | Trigger Coupling| AC, LF REJ, HF REJ, or DC }} | {{Spec | Trigger Coupling | AC, LF REJ, HF REJ, or DC }} | ||
{{Spec | Probes| Two P6108A 100 MHz | {{Spec | Vertical modes | CH1, ALT, CHOP (~275 kHz), ADD, CH2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz) }} | ||
{{Spec | Power| 40 W max, 90 − | {{Spec | Horizontal modes | A or B Sweep, A/B Alternate, B Delayed, X-Y }} | ||
{{Spec | Extra inputs | A Trigger Ext (front), B Trigger Ext (front), External Z-Axis (rear) }} | |||
{{Spec | Probes | Two [[P6108A]] 100 MHz ×10 probes, BNC connector with a readout pin }} | |||
{{Spec | Power | 40 W max, 90 − 250 V<sub>AC</sub>, 48 − 440 Hz }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | ==Links== | ||
{{Documents|Link=2336}} | |||
==Prices== | |||
{| class="wikitable" | |||
|- | |||
! Year | |||
! 1982 | |||
|- | |||
! Catalog Price | |||
| $3,075 | |||
|- | |||
! In 2023 Dollars | |||
| $9,800 | |||
|} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tektronix 2336.jpg | |||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|2336}} | |||
[[Category:2300 series scopes]] |
Latest revision as of 14:02, 27 October 2023
The Tektronix 2336 is a ruggedized portable dual-channel, 100 MHz analog scope. The front cover contains a 3 ½ digit LCD for delta time measurements and B trigger function. A 150 MHz modification was available.
The 2336YA is reportedly the same with only a Curtis elapsed time meter added, and two P6101 probes included.
Key Specifications
Bandwidth | 100 MHz (≥88 MHz at 2 mV/div) |
---|---|
Deflection | 5 mV/div to 5 V/div (1−2−5 sequence), ±3%; Variable control can increase sensitivity to at least 2 mV/div |
Input Impedance | 1 MΩ ±2% // 20 pF ±10%, 2 channels |
Maximum Input Voltage | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) |
Sweep | A Time Base: 0.5 s/div to 50 ns/div, 1−2−5; B Time Base: 50 ms/div to 50 ns/div, 1−2−5; A and B ×10 magnifier extends max sweep to 5 ns/div |
Trigger Source | VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10 |
Trigger Coupling | AC, LF REJ, HF REJ, or DC |
Vertical modes | CH1, ALT, CHOP (~275 kHz), ADD, CH2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz) |
Horizontal modes | A or B Sweep, A/B Alternate, B Delayed, X-Y |
Extra inputs | A Trigger Ext (front), B Trigger Ext (front), External Z-Axis (rear) |
Probes | Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin |
Power | 40 W max, 90 − 250 VAC, 48 − 440 Hz |
Links
Documents Referencing 2336
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1981 V13 N2.pdf | Article | Three New Portable Oscilloscopes Designed for Field Service Use | Peter Zietzke | 1981 | 2335 • 2336 • 2337 |
Prices
Year | 1982 |
---|---|
Catalog Price | $3,075 |
In 2023 Dollars | $9,800 |
Pictures
Components
Some Parts Used in the 2336
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
155-0124-00 | 155-0124-00 | Monolithic integrated circuit | horizontal preamplifier | 455 • SC503 • SC504 • 2221 • 2230 • 2232 • 2336 • 2337 |
155-0219-00 | 155-0219-00 | Hybrid integrated circuit | output amplifier | 2335 • 2336 • 2337 |
155-0220-00 | 155-0217-00 | Hybrid integrated circuit | amplifier | 2335 • 2336 • 2337 |