2336: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(7 intermediate revisions by 3 users not shown)
Line 10: Line 10:
|designers=
|designers=
|manuals=
|manuals=
* [[Media:Tek_2336_YA_Operators_Manual.pdf| Tektronix 2336 YA Operators Manual ]] (PDF)
* [[Media:070-4118-00.pdf|Tektronix 2336 Service Manual]]
* [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF)
* [[Media:070-5010-00.pdf|Tektronix 2336 YA Operators Manual 070-5010-00]]  
* [[Media:070-5010-00.pdf| Tektronix 2336 YA Operators Manual ]] (PDF, OCR)
* [[Media:070-5011-00.pdf|Tektronix 2336 YA Service Manual 070-5011-00]]
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF, OCR)
* [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure]]
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure]] (OCR)
}}
}}
The '''Tektronix 2336''' is a ruggedized portable dual-channel, 100 MHz analog scope. An A Ext connector (external signal to the A Trigger Generator) on the front panel, B Ext connector (external signal to the B Trigger Generator) on the front cover, and External Z-Axis connector at the rear round out its connectivity.  The front cover also has a 3 ½ digit LCD for delta TIME measurements and B Trigger function.  A 150 MHz modification was available.
The '''Tektronix 2336''' is a ruggedized portable dual-channel, 100 MHz analog scope. The front cover contains a 3 ½ digit LCD for delta time measurements and B trigger function.  A 150 MHz modification was available.


Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling.  The vertical mode selections are CH 1, ALT, CHOP (~275 kHz), ADD, CH 2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz).  Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep.
The '''2336YA''' is reportedly the same with only a Curtis [[elapsed time meter]] added, and two [[P6101]] probes included.
 
Trigger sources may be VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10.  Trigger coupling can be AC, LF REJ, HF REJ, or DC, and can be controlled by amplitude level and slope type.  The Trigger Modes may be set to AUTO, NORM, and SGL SWP.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth | 100 MHz (≥88 MHz at 2 mV/div) }}
{{Spec | Bandwidth             | 100 MHz (≥88 MHz at 2 mV/div) }}
{{Spec | Deflection | 5 mV/div to 5 V/div (1−2−5 sequence), ±3%; Variable control can increase sensitivity to at least 2 mV/div}}
{{Spec | Deflection           | 5 mV/div to 5 V/div (1−2−5 sequence), ±3%; Variable control can increase sensitivity to at least 2 mV/div}}
{{Spec | Input Impedance | 1 MΩ ±2% // 20 pF ±10%, 2 channels }}
{{Spec | Input Impedance       | 1 MΩ ±2% // 20 pF ±10%, 2 channels }}
{{Spec | Maximum Input Voltage| 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }}
{{Spec | Maximum Input Voltage | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }}
{{Spec | Sweep | A Time Base: 0.5 s/div to 50 ns/div, 1−2−5; B Time Base: 50 ms/div to 50 ns/div, 1−2−5; A and B ×10 magnifier extends max sweep to 5 ns/div }}
{{Spec | Sweep                 | A Time Base: 0.5 s/div to 50 ns/div, 1−2−5; B Time Base: 50 ms/div to 50 ns/div, 1−2−5; A and B ×10 magnifier extends max sweep to 5 ns/div }}
{{Spec | Trigger Source| VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10 }}
{{Spec | Trigger Source       | VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10 }}
{{Spec | Trigger Coupling| AC, LF REJ, HF REJ, or DC }}
{{Spec | Trigger Coupling     | AC, LF REJ, HF REJ, or DC }}
{{Spec | Probes| Two [[P6108A]] 100 MHz ×10 probes, BNC connector with a readout pin }}
{{Spec | Vertical modes        | CH1, ALT, CHOP (~275 kHz), ADD, CH2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz) }}
{{Spec | Power| 40 W max, 90 − 250 V<sub>AC</sub>, 48 − 440 Hz }}
{{Spec | Horizontal modes      | A or B Sweep, A/B Alternate, B Delayed, X-Y }}
{{Spec | Extra inputs          | A Trigger Ext (front), B Trigger Ext (front), External Z-Axis (rear) }}
{{Spec | Probes               | Two [[P6108A]] 100 MHz ×10 probes, BNC connector with a readout pin }}
{{Spec | Power                 | 40 W max, 90 − 250 V<sub>AC</sub>, 48 − 440 Hz }}
{{EndSpecs}}
{{EndSpecs}}


==Links==
==Links==
* [[Media:Tekscope 1981 V13 N2.pdf  | TekScope Vol. 13 No. 2, June 1981]] p.10+: Three New Portable Oscilloscopes Designed for Field Service Use
{{Documents|Link=2336}}
 
==Prices==
 
{| class="wikitable"
|-
! Year
! 1982
|-
! Catalog Price
| $3,075
|-
! In 2023 Dollars
| $9,800
|}


==Pictures==
==Pictures==
Line 42: Line 58:
</gallery>
</gallery>


[[Category:2300 series scopes]]
==Components==
{{Parts|2336}}
 
[[Category:2300 series scopes]]

Latest revision as of 14:02, 27 October 2023

Tektronix 2336
Ruggedized 100 MHz dual trace scope
Tektronix 2336

Produced from 1982 to 1991

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 2336 is a ruggedized portable dual-channel, 100 MHz analog scope. The front cover contains a 3 ½ digit LCD for delta time measurements and B trigger function. A 150 MHz modification was available.

The 2336YA is reportedly the same with only a Curtis elapsed time meter added, and two P6101 probes included.

Key Specifications

Bandwidth 100 MHz (≥88 MHz at 2 mV/div)
Deflection 5 mV/div to 5 V/div (1−2−5 sequence), ±3%; Variable control can increase sensitivity to at least 2 mV/div
Input Impedance 1 MΩ ±2% // 20 pF ±10%, 2 channels
Maximum Input Voltage 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz)
Sweep A Time Base: 0.5 s/div to 50 ns/div, 1−2−5; B Time Base: 50 ms/div to 50 ns/div, 1−2−5; A and B ×10 magnifier extends max sweep to 5 ns/div
Trigger Source VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10
Trigger Coupling AC, LF REJ, HF REJ, or DC
Vertical modes CH1, ALT, CHOP (~275 kHz), ADD, CH2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz)
Horizontal modes A or B Sweep, A/B Alternate, B Delayed, X-Y
Extra inputs A Trigger Ext (front), B Trigger Ext (front), External Z-Axis (rear)
Probes Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin
Power 40 W max, 90 − 250 VAC, 48 − 440 Hz

Links

Documents Referencing 2336

Document Class Title Authors Year Links
Tekscope 1981 V13 N2.pdf Article Three New Portable Oscilloscopes Designed for Field Service Use Peter Zietzke 1981

Prices

Year 1982
Catalog Price $3,075
In 2023 Dollars $9,800

Pictures

Components

Some Parts Used in the 2336

Part Part Number(s) Class Description Used in
155-0124-00 155-0124-00 Monolithic integrated circuit horizontal preamplifier 455 SC503 SC504 2221 2230 2232 2336 2337
155-0219-00 155-0219-00 Hybrid integrated circuit output amplifier 2335 2336 2337
155-0220-00 155-0217-00 Hybrid integrated circuit amplifier 2335 2336 2337