The Tektronix 067-0502-01 is | {{Instrument Sidebar | ||
voltage or current waveform and/or to compare an external unknown input with an internal or | |manufacturer=Tektronix | ||
external reference. | |model=067-0502-01 | ||
|class=Signal generator | |||
|series= | |||
|summary=Amplitude Calibrator | |||
|image=Tek 067-0502-01.JPG | |||
|caption= | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:062-1105-00.pdf|Tektronix 067-0502-01 Manual]] (OCR) | |||
}} | |||
The '''Tektronix 067-0502-01 Amplitude Calibrator and Comparator''' is an instrument that can be used to produce a reference rectangle voltage or current waveform and/or to compare an external unknown input with an internal or external reference. | |||
The | The output voltage is only accurate if terminated in 1 MΩ, the 50 V setting will experience the highest error if not properly terminated (0.5% in an open load). | ||
The comparison is performed using an [[Airpax A175]] chopper to switch between the two voltages that are being compared. | |||
The resulting output is a rectangular waveform with amplitude equal to the difference of two voltages. | |||
This waveform can be amplified using a drift-free AC amplifier and viewed on an oscilloscope for high sensitivity comparison. | |||
See the [[067-0502-00]] page for a comparison of the -00 and -01 models. | |||
The HV supply uses a tube V427, to regulate the +300V supply. The manual lists V427 as a [[7734]], a triode-pentode, however some models contain a small circular adapter board (670-1860-00, 388-2423-00) to adapt the [[B9A_base|noval tube socket]] to a [[Compactron_base|Compactron socket]] and use a [[6G11]] double pentode instead. The adapter PCB connects the screen grid and plate of the beam power tube together in a triode configuration. These models also have [[6G11]] printed below V427 on the chassis. | |||
The output amplitude can be reduced down to 0.2 μV using the [[067-0529-00]] 1000:1 precision divider. | |||
{{BeginSpecs}} | |||
{{Spec | Output | DC+, DC-, Squarewave}} | |||
{{Spec | Amplitude range | 0.2 mV to 100 V in 1-2-5 sequence, 5mA in current loop}} | |||
{{Spec | Amplitude accuracy | Within 0.25% into 1 MΩ load}} | |||
{{Spec | Squarewave repetition rate | 1 kHz within 20% }} | |||
{{Spec | Maximum input voltage | 100 V }} | |||
{{EndSpecs}} | |||
==Links== | |||
* [https://www.youtube.com/watch?v=a1uvoqf4wLc Tektronix 067-0502-01 Repair and Calibration] | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek 067-0502-01.JPG|067-0502-01 | |||
067-0502-01 schem.png|067-0502-01 Schematic | |||
Tek 067-0502.JPG|067-0502 | |||
Tek 067-0502-01 rear.jpg|067-0502-01 rear | |||
Tek 067-0502-01 bottom.jpg|067-0502-01 bottom | |||
Tek 067-0502-01 front.jpg|067-0502-01 front | |||
067-0502-01-interior.jpg|067-0502-01 internal view | |||
067-0502-01-interior_det.jpg|067-0502-01 internal detail with 6G11 as V427 | |||
</gallery> | </gallery> | ||
{{Parts|067-0502-01}} | |||
[[Category:Calibration fixtures]] | [[Category:Calibration fixtures]] | ||
[[Category:Amplitude Calibrators]] |
Latest revision as of 20:47, 15 November 2023
The Tektronix 067-0502-01 Amplitude Calibrator and Comparator is an instrument that can be used to produce a reference rectangle voltage or current waveform and/or to compare an external unknown input with an internal or external reference.
The output voltage is only accurate if terminated in 1 MΩ, the 50 V setting will experience the highest error if not properly terminated (0.5% in an open load).
The comparison is performed using an Airpax A175 chopper to switch between the two voltages that are being compared. The resulting output is a rectangular waveform with amplitude equal to the difference of two voltages. This waveform can be amplified using a drift-free AC amplifier and viewed on an oscilloscope for high sensitivity comparison.
See the 067-0502-00 page for a comparison of the -00 and -01 models.
The HV supply uses a tube V427, to regulate the +300V supply. The manual lists V427 as a 7734, a triode-pentode, however some models contain a small circular adapter board (670-1860-00, 388-2423-00) to adapt the noval tube socket to a Compactron socket and use a 6G11 double pentode instead. The adapter PCB connects the screen grid and plate of the beam power tube together in a triode configuration. These models also have 6G11 printed below V427 on the chassis.
The output amplitude can be reduced down to 0.2 μV using the 067-0529-00 1000:1 precision divider.
Key Specifications
Output | DC+, DC-, Squarewave |
---|---|
Amplitude range | 0.2 mV to 100 V in 1-2-5 sequence, 5mA in current loop |
Amplitude accuracy | Within 0.25% into 1 MΩ load |
Squarewave repetition rate | 1 kHz within 20% |
Maximum input voltage | 100 V |
Links
Pictures
-
067-0502-01
-
067-0502-01 Schematic
-
067-0502
-
067-0502-01 rear
-
067-0502-01 bottom
-
067-0502-01 front
-
067-0502-01 internal view
-
067-0502-01 internal detail with 6G11 as V427
Some Parts Used in the 067-0502-01
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
6G11 | 154-0660-00 | Vacuum Tube (Pentode) | double sharp cut-off beam power pentode | 125 • 132 • 519 • 067-0502-01 • 050-0551-00 |