544: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The Type 544 is a | {{Oscilloscope Sidebar| | ||
It has one timebase. | title=Tektronix 544| | ||
The timebase has several horizontal magnifier modes: | image=Tek 544.jpg| | ||
x2, x5, x10, x20, x50, and x100. | caption=Tektronix 544, front view| | ||
To make horizontal magnification usable, the 544 has a | years=1964 — ?| | ||
vernier horizontal position control in addition to the | summary=50 MHz oscilloscope| | ||
manuals= | |||
* [http://bama.edebris.com/download/tek/544/544.djvu Tektronix 544 Manual (DjVu)] | |||
* [http://w140.com/tek_544.pdf Tektronix 544 Manual (PDF)] | |||
* [http://w140.com/Hi-speed_recorder.pdf General Electric Report from 1968 Discussing Tek 544 Mod 108G (PDF)] | |||
}} | |||
The Type 544 is a 50 MHz scope [[introduced in 1964]]. It has one timebase. | |||
The timebase has several horizontal magnifier modes: x2, x5, x10, x20, x50, and x100. | |||
To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the | |||
regular horizontal position control. | regular horizontal position control. | ||
The fastest calibrated sweep is | The fastest calibrated sweep is 10 ns/div. | ||
Some magnification modes provide | Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that. | ||
sweeps faster than | |||
but in those modes the horizontal scale is not calibrated, | |||
and a lamp on the front panel lights up | |||
to remind the operator of that | |||
The 544 (at least the early ones) uses the same [[tunnel diodes|tunnel diode]] triggering circuit | |||
as is used in early [[547]] (tunnel diode in the collector load of a PNP differential amplifier). | |||
A factory modification, MOD 108G, was available that increased the accelerating voltage to 24kv. | |||
The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1ns risetime. | |||
The | |||
The vertical amplifier and low voltage power supply of the 544 are the same as those of the [[546]] and [[547]]. | |||
The 544 uses the [[154-0478-00]] CRT which is also used by the [[543|543B]], [[545|545B]], [[546]], and [[547]]. | |||
<gallery> | <gallery> | ||
Line 36: | Line 31: | ||
File:Tek rm544.jpg|RM544 front view | File:Tek rm544.jpg|RM544 front view | ||
</gallery> | </gallery> | ||
[[Category:Tube scopes]] | |||
[[Category:Specifications needed] |
Revision as of 03:30, 9 May 2014
The Type 544 is a 50 MHz scope introduced in 1964. It has one timebase.
The timebase has several horizontal magnifier modes: x2, x5, x10, x20, x50, and x100.
To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the
regular horizontal position control.
The fastest calibrated sweep is 10 ns/div.
Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that.
The 544 (at least the early ones) uses the same tunnel diode triggering circuit as is used in early 547 (tunnel diode in the collector load of a PNP differential amplifier).
A factory modification, MOD 108G, was available that increased the accelerating voltage to 24kv. The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1ns risetime.
The vertical amplifier and low voltage power supply of the 544 are the same as those of the 546 and 547. The 544 uses the 154-0478-00 CRT which is also used by the 543B, 545B, 546, and 547.
-
544 front view
-
RM544 front view
[[Category:Specifications needed]