|summary=High Current Transformer | |||
|image=Tek ct-5 1.JPG | |||
|caption=CT-5 High Current Transformer | |||
|for=A6302 | |||
|introduced=1971 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-1130-00.pdf|Tektronix CT-5 Manual]] | |||
}} | |||
The '''Tektronix CT-5 High Current Transformer''' is designed to extend the range of an [[A6302]] probe (with [[AM503]] amplifier) or [[P6021]] probe by a factor of 1000 (up to 5000 A/Div). | The '''Tektronix CT-5 High Current Transformer''' is designed to extend the range of an [[A6302]] probe (with [[AM503]] amplifier) or [[P6021]] probe by a factor of 1000 (up to 5000 A/Div). | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 0.5 Hz to 20 MHz with A6302; 12 Hz to 20 MHz with P6021; 1 Hz to 1 MHz with A6302/DC Bucking Coil}} | |||
{{Spec | Risetime | 17.5 ns }} | |||
{{Spec | Maximum pulsed current | 50 kA peak (with dearating)}} | |||
{{Spec | Accuracy | 4 % }} | |||
{{Spec | Attenuation | 20:1 or 1000:1 }} | |||
{{Spec | Input impedance | 20 µΩ at 60 Hz to 30 mΩ at 1 MHz }} | |||
{{Spec | Max. input voltage | 3000 V (bare conductor) }} | |||
{{EndSpecs}} | |||
==Links== | |||
{{PatentLinks|CT-5}} | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek CT-5 Box close.jpeg | |||
Tek CT-5 Box open.jpeg | |||
Tek CT-5 Box label.jpeg | |||
Tek CT-5 Probe left.jpeg | |||
Tek CT-5 Probe right.jpeg | |||
Tek CT-5 Probe open.jpeg | |||
Tek CT-5 Probe connection.jpeg | |||
Tek CT-5 DC bucking coil right.jpeg | |||
Tek CT-5 DC bucking coil left.jpeg | |||
Tek ct-5 1.JPG | |||
Tek ct-5 2.JPG | |||
</gallery> | </gallery> | ||
[[Category:Oscilloscope current probes]] | |||
[[Category:Oscilloscope |
Latest revision as of 04:32, 19 June 2024
The Tektronix CT-5 High Current Transformer is designed to extend the range of an A6302 probe (with AM503 amplifier) or P6021 probe by a factor of 1000 (up to 5000 A/Div).
Key Specifications
Bandwidth | 0.5 Hz to 20 MHz with A6302; 12 Hz to 20 MHz with P6021; 1 Hz to 1 MHz with A6302/DC Bucking Coil |
---|---|
Risetime | 17.5 ns |
Maximum pulsed current | 50 kA peak (with dearating) |
Accuracy | 4 % |
Attenuation | 20:1 or 1000:1 |
Input impedance | 20 µΩ at 60 Hz to 30 mΩ at 1 MHz |
Max. input voltage | 3000 V (bare conductor) |