Latest revision as of 04:32, 19 June 2024
The Tektronix CT-5 High Current Transformer is designed to extend the range of an A6302 probe (with AM503 amplifier) or P6021 probe by a factor of 1000 (up to 5000 A/Div).
Key Specifications
Bandwidth | 0.5 Hz to 20 MHz with A6302; 12 Hz to 20 MHz with P6021; 1 Hz to 1 MHz with A6302/DC Bucking Coil |
---|---|
Risetime | 17.5 ns |
Maximum pulsed current | 50 kA peak (with dearating) |
Accuracy | 4 % |
Attenuation | 20:1 or 1000:1 |
Input impedance | 20 µΩ at 60 Hz to 30 mΩ at 1 MHz |
Max. input voltage | 3000 V (bare conductor) |
Links
Patents that may apply to CT-5
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 3708749A | Current transformer | Glenn Bateman • John A. Roberts | 1971-03-18 | 1973-01-02 | CT-5 |