P6135: Difference between revisions
Jump to navigation
Jump to search
(new in 1987 catalog) |
No edit summary |
||
(18 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
The '''Tektronix | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=P6135 | |||
|summary=150 MHz, ×10 differential probe pair | |||
|image=Tek p6135 1.jpg | |||
|caption=Tektronix P6135 | |||
|for=1 MΩ scope inputs | |||
|series= | |||
|introduced=1987 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-7675-02.pdf|Tektronix P6135A Manual]] | |||
}} | |||
The '''Tektronix P6135(A)''' is a differential probe pair matched to minimize differences in impedance and signal delay, | |||
to maintain CMRR up to 20,000:1 when used with differential amplifiers such as the [[7A13]], [[7A22]] or [[11A33]]. | |||
The P6135 is a [[Subminiature modular probes|subminiature modular probe]] with a limited compensation range around 15 pF. | |||
The P6135A is a larger [[compact modular probes|compact modular probe]] and comes with three different tips for increased compensation range, matching the [[11A33]] − red, [[7A13]] − black, and [[7A22]] − blue. | |||
The P6135A model can therefore be seen as a replacement of the [[P6055]]. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Scope | {{Spec | Scope Impedance Compensation Range | P6135: 1 MΩ // 13-17 pF; P6135A: 1 MΩ // 13-17 pF (red tip), 1 MΩ // 18-22 pF (black tip) and 1 MΩ // 45-49 pF (blue tip) }} | ||
{{Spec | Attenuation | Adjustable to ×10 }} | {{Spec | Attenuation | Adjustable to ×10 }} | ||
{{Spec | CMRR | 10,000:1 on [[11A33]], 20,000:1 on [[7A13]] }} | {{Spec | CMRR | 10,000:1 on [[11A33]], 20,000:1 on [[7A13]] }} | ||
{{Spec | Bandwidth | 150 MHz}} | |||
{{Spec | Max. input | ±500 V Maximum Common Mode Voltage }} | {{Spec | Max. input | ±500 V Maximum Common Mode Voltage }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | |||
===P6135=== | |||
<gallery> | |||
Tek p6135 1.jpg | |||
Tek p6135 2.jpg | |||
Tek p6135 3.jpg | |||
Tek p6135 4.jpg | |||
</gallery> | |||
===P6135A=== | |||
<gallery> | |||
P6135A_1.jpg | |||
</gallery> | |||
[[Category: | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:Passive Differential probes]] | |||
[[Category:Subminiature modular probes]] |
Revision as of 04:20, 18 July 2024
The Tektronix P6135(A) is a differential probe pair matched to minimize differences in impedance and signal delay, to maintain CMRR up to 20,000:1 when used with differential amplifiers such as the 7A13, 7A22 or 11A33.
The P6135 is a subminiature modular probe with a limited compensation range around 15 pF. The P6135A is a larger compact modular probe and comes with three different tips for increased compensation range, matching the 11A33 − red, 7A13 − black, and 7A22 − blue. The P6135A model can therefore be seen as a replacement of the P6055.
Key Specifications
Scope Impedance Compensation Range | P6135: 1 MΩ // 13-17 pF; P6135A: 1 MΩ // 13-17 pF (red tip), 1 MΩ // 18-22 pF (black tip) and 1 MΩ // 45-49 pF (blue tip) |
---|---|
Attenuation | Adjustable to ×10 |
CMRR | 10,000:1 on 11A33, 20,000:1 on 7A13 |
Bandwidth | 150 MHz |
Max. input | ±500 V Maximum Common Mode Voltage |