{{Probe Sidebar | |||
The '''Tektronix P6013''' is a | |manufacturer=Tektronix | ||
|model=P6013 | |||
|summary=25 MHz ×1000 HV probe | |||
|image=Tek P6013 in box.jpg | |||
|caption=Tektronix P6013 | |||
|for=1 MΩ scope inputs | |||
|introduced=1961 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-321.pdf|Tektronix P6013 manual]] | |||
}} | |||
The '''Tektronix P6013''' is a ×1000 high-voltage oscilloscope probe. | |||
It was updated as the [[P6013A]] in 1966. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Input impedance | 100 MΩ // 3 pF }} | {{Spec | Input impedance | 100 MΩ // 3 pF }} | ||
{{Spec | Attenuation | 1 | {{Spec | Attenuation | 1000 : 1 }} | ||
{{Spec | | {{Spec | Rise time | 14 ns (specified with [[545B]] and [[K|Type K]]) }} | ||
{{Spec | Input voltage | 12 kV max. ( | {{Spec | Bandwidth | 25 MHz }} | ||
{{Spec | | {{Spec | Input voltage | 12 kV max. DC+peak AC (derate above 100 kHz) }} | ||
{{Spec | Output | [[UHF connector]] }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
== | ==Links== | ||
{{Documents|Link=P6013}} | |||
==Pictures== | |||
<gallery> | |||
Tek P6013 in box.jpg | |||
Tek p6013 in 1963 catalog.jpg|P6013 in 1963 Catalog | |||
Tek p6013 2.jpg|Probe core without plastic housing | |||
Tek p6013 1.jpg|Probe core without plastic housing | |||
Tek p6013 comp box2.jpg|Compensation box | |||
Tek p6013 comp box1.jpg|Compensation box internal | |||
Tek p6013 internal1.jpg|Probe internal | |||
Tek p6013 internal2.jpg|Probe internal. See white spiral insulator that splays flanges for compensation adjustment | |||
</gallery> | |||
{{BetterPics}} | |||
[[Category:1 | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:High | [[Category:High voltage oscilloscope probes]] |
Latest revision as of 03:37, 12 March 2024
The Tektronix P6013 is a ×1000 high-voltage oscilloscope probe.
It was updated as the P6013A in 1966.
Key Specifications
Input impedance | 100 MΩ // 3 pF |
---|---|
Attenuation | 1000 : 1 |
Rise time | 14 ns (specified with 545B and Type K) |
Bandwidth | 25 MHz |
Input voltage | 12 kV max. DC+peak AC (derate above 100 kHz) |
Output | UHF connector |
Links
Documents Referencing P6013
- (no results)
Pictures
-
-
P6013 in 1963 Catalog
-
Probe core without plastic housing
-
Probe core without plastic housing
-
Compensation box
-
Compensation box internal
-
Probe internal
-
Probe internal. See white spiral insulator that splays flanges for compensation adjustment
Better pictures needed - please contribute