Telequipment D83: Difference between revisions
(Created page with "{{Oscilloscope Sidebar | title=Telequipment D83 | summary=50 MHz scope | image=Telequipment D83.jpg | caption=Telequipment D83 | introduced=(?) | discontinued=(?) | manuals= ...") |
m (Another photo) |
||
(18 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | ||
|manufacturer=Telequipment | |||
summary=50 MHz scope | | |series=Telequipment D63 DM63 D75 D83 | ||
image=Telequipment D83.jpg | | |model=D83 | ||
caption=Telequipment D83 | | |summary=50 MHz scope | ||
introduced= | |image=Telequipment D83.jpg | ||
discontinued=(?) | | |caption=Telequipment D83 | ||
manuals= | |introduced=1972 | ||
* [[Media:Telequipment_d83_oscilloscope_sm.pdf | D83 Service Manual]] | |discontinued=(?) | ||
|designers= | |||
|manuals= | |||
* [[Media:Telequipment_d83_oscilloscope_sm.pdf | D83 Service Manual]] | |||
}} | }} | ||
The '''Telequipment D83''' is a 50 MHz | The '''Telequipment D83''' is a 50 MHz CRO. It is a larger-screen, upright version of the [[Telequipment D75]]. | ||
The | The D83 takes two plug-ins that are also compatible with [[Telequipment D75|D75]], [[Telequipment D63|D63]] and [[Telequipment DM63|DM63]]. | ||
Vertical plugins include the [[Telequipment V4|V4 dual trace amplifiers]], the [[Telequipment V3|V3 single channel differential amplifier]], the [[Telequipment V1|V1 single channel amplifier]], and the [[Telequipment V5|V5 single channel amplifier with delay line]] (primarily intended for the DM63/D63 mainframes that have no built-in delay lines, whereas D75/D83 do). Timebase plugins include the [[Telequipment | Vertical plugins include the [[Telequipment V4|V4 dual trace amplifiers]], the [[Telequipment V3|V3 single channel differential amplifier]], the [[Telequipment V1|V1 single channel amplifier]], and the [[Telequipment V5|V5 single channel amplifier with delay line]] (primarily intended for the DM63/D63 mainframes that have no built-in delay lines, whereas D75/D83 do). Timebase plugins include the [[Telequipment S1|S1 single timebase]] and [[Telequipment S2|S2 dual timebase]]. | ||
{{ | '''NB''' There's a chance of some confusion with the input specs below. While the service manual states input impedance, that's for the Z modulation on the main frame. This text will be removed once the specs for the plug-ins (see above) are made available on their own pages. The weight stated in the various documentation (service manual, operator manual, catalogue, etc) differs, too. | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | DC to 50 MHz (−3 dB), AC coupled ≥2 Hz }} | |||
{{Spec | Risetime | 7 ns }} | |||
{{Spec | Deflection | 5 mV/div to 20 V/div in 12 calibrated steps (1−2−5 sequence) }} | |||
{{Spec | Timebase | 2 s/div (B: 1 s/div) to 100 ns/div, 1−2–5 }} | |||
{{Spec | Input impedance | 1 MΩ // 29 pF }} | |||
{{Spec | Max. input | max. 400 V DC + peak AC }} | |||
{{Spec | Trigger modes | A: Auto, DC, AC, HF Reject; B: Auto, AC }} | |||
{{Spec | Trigger Sources | CH1, CH2, Alternate }} | |||
{{Spec | Operating modes | CH1, CH2, Alt, Chopped, Add; CH2 can be inverted }} | |||
{{Spec | Sweep modes | A only, A intensified by B, B delayed by A, A and B mixed, delayed B variable or triggered, repetitive or single shot }} | |||
{{Spec | Delay time | 10 μs to 20 s }} | |||
{{Spec | Calibrator | ~1 kHz, 30 mV and 300 mV, 3 mA, square wave, ±1% voltage and current, ±20% frequency}} | |||
{{Spec | CRT | [[154-0640-05]] tube, P31 [[phosphor]], 15 kV acceleration (–2.5/+12.5), 8 × 10 graticule, 1.2 cm per division }} | |||
{{Spec | Power | 100−125 V in 5 V steps, 200−250 V in 10 V steps, selected via primary voltage selector, 48–400 Hz, 85 VA }} | |||
{{Spec | Dimensions | 290 mm (H) × 215 mm (W) × 520 mm (D) }} | |||
{{Spec | Weight | 9.5 kg (mainframe), 14 kg with plug-ins }} | |||
{{Spec | Environment | Operating: +5°C to +40°C, Non-operating: –25°C to +70°C }} | |||
{{EndSpecs}} | |||
==Links== | ==Links== | ||
* [https://www.radiomuseum.org/r/telequip_d83d_8.html Telequipment D83 @ radiomuseum.org] | * [https://www.radiomuseum.org/r/telequip_d83d_8.html Telequipment D83 @ radiomuseum.org] | ||
* [http://www.richardsradios.co.uk/telequipmentd83.html Telequipment D83 @ richardsradios.co.uk] | * [http://www.richardsradios.co.uk/telequipmentd83.html Telequipment D83 @ richardsradios.co.uk] | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tq d83 1.jpg | |||
Tq d83 2.jpg | |||
Telequipment d83 with v4 and s2c.jpg | |||
</gallery> | |||
==Components== | |||
{{CRTs|Telequipment D83}} | |||
[[Category:plugin scopes]] | |||
[[Category:CRT based solid-state scopes]] | |||
[[Category:Telequipment]] |
Latest revision as of 10:04, 19 October 2023
The Telequipment D83 is a 50 MHz CRO. It is a larger-screen, upright version of the Telequipment D75.
The D83 takes two plug-ins that are also compatible with D75, D63 and DM63. Vertical plugins include the V4 dual trace amplifiers, the V3 single channel differential amplifier, the V1 single channel amplifier, and the V5 single channel amplifier with delay line (primarily intended for the DM63/D63 mainframes that have no built-in delay lines, whereas D75/D83 do). Timebase plugins include the S1 single timebase and S2 dual timebase.
NB There's a chance of some confusion with the input specs below. While the service manual states input impedance, that's for the Z modulation on the main frame. This text will be removed once the specs for the plug-ins (see above) are made available on their own pages. The weight stated in the various documentation (service manual, operator manual, catalogue, etc) differs, too.
Key Specifications
Bandwidth | DC to 50 MHz (−3 dB), AC coupled ≥2 Hz |
---|---|
Risetime | 7 ns |
Deflection | 5 mV/div to 20 V/div in 12 calibrated steps (1−2−5 sequence) |
Timebase | 2 s/div (B: 1 s/div) to 100 ns/div, 1−2–5 |
Input impedance | 1 MΩ // 29 pF |
Max. input | max. 400 V DC + peak AC |
Trigger modes | A: Auto, DC, AC, HF Reject; B: Auto, AC |
Trigger Sources | CH1, CH2, Alternate |
Operating modes | CH1, CH2, Alt, Chopped, Add; CH2 can be inverted |
Sweep modes | A only, A intensified by B, B delayed by A, A and B mixed, delayed B variable or triggered, repetitive or single shot |
Delay time | 10 μs to 20 s |
Calibrator | ~1 kHz, 30 mV and 300 mV, 3 mA, square wave, ±1% voltage and current, ±20% frequency |
CRT | 154-0640-05 tube, P31 phosphor, 15 kV acceleration (–2.5/+12.5), 8 × 10 graticule, 1.2 cm per division |
Power | 100−125 V in 5 V steps, 200−250 V in 10 V steps, selected via primary voltage selector, 48–400 Hz, 85 VA |
Dimensions | 290 mm (H) × 215 mm (W) × 520 mm (D) |
Weight | 9.5 kg (mainframe), 14 kg with plug-ins |
Environment | Operating: +5°C to +40°C, Non-operating: –25°C to +70°C |
Links
Pictures
Components
CRTs used in the Telequipment D83
Page | Part nos | Description | Designers | Used in |
---|---|---|---|---|
T7400 | 154-0640-00 • 154-0640-05 • 154-0640-31 • 154-0640-10 • 154-0672-00 • 154-0673-00 • 154-0822-00 • 154-0823-00 | large-screen CRT (8 × 10 divisions of 1.22 cm) | 7403N • 7603 • Telequipment D83 |