2711: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Instrument Sidebar  
title=Tektronix 2711 |
|class=Spectrum Analyzer
summary=Spectrum Analyzer 9 kHz to 1.8 GHz |
|manufacturer=Tektronix  
image= Tek_2711_Waveform_image.jpg |
|model=2711 |
caption=Tektronix 2711 |
|summary=1.8 GHz Spectrum Analyzer  
introduced=1993 |
|image= Tek_2711_Waveform_image.jpg  
discontinued=(?) |
|caption=Tektronix 2711  
manuals=
|introduced=1993  
Need User Manual
|discontinued=(?)  
* [[Media:070-8130-04.pdf | Tektronix 2711 Service Manual (PDF)]]
|manuals=
* [[Media:070-8132-01.pdf | Tektronix 2711 & 2712 GPIB Programmer Manual (PDF)]]
* [[Media:070-8500-00.pdf|Tektronix 2711 User Manual]]
* [[Media:070-8130-04.pdf|Tektronix 2711 Service Manual]]
* [[Media:070-8132-01.pdf|Tektronix 2711 & 2712 GPIB Programmer Manual]]
}}
}}
The '''Tektronix 2711''' is a spectrum analyzer with a frequency range of 9 kHz to 1.8 GHz.  The minimum resolution bandwidth is 3 kHz, and provides measurement resolution proportional to the frequency accuracy or span.  With non-volatile memory (NVRAM) at 28 kB can save up to 18* displays of waveforms and markers, and up to 9* front panel setups, large user-defined key programs, and antenna factor tables.  * Opt. 03 adds additional NVRAM bringing saved displays to 108, and 36 front panel setups.
The '''Tektronix 2711''' is a spectrum analyzer with a frequency range of 9 kHz to 1.8 GHz.  The minimum resolution bandwidth is 3 kHz, and provides measurement resolution proportional to the frequency accuracy or span.  With non-volatile memory (NVRAM) at 28 kB can save up to 18* displays of waveforms and markers, and up to 9* front panel setups, large user-defined key programs, and antenna factor tables.  * Opt. 03 adds additional NVRAM bringing saved displays to 108, and 36 front panel setups.


Line 25: Line 26:


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Frequency Range | 9 kHz to 1.8 GHz }}
{{Spec | Frequency | 9 kHz to 1.8 GHz }}
{{Spec | Frequency Span Range (plus 0 Hz and MAX: 180 MHz/div) | 10 kHz/div to 100 MHz/div in 1, 2, 5 sequence }}
{{Spec | Frequency Span | 10 kHz/div to 100 MHz/div in 1, 2, 5 sequence (plus 0 Hz and MAX: 180 MHz/div)}}
{{Spec | Resolution Bandwidth Range | -6 dB bandwidth selections are 3 kHz, 30 kHz, 300 kHz, and 5 MHz }}
{{Spec | Resolution Bandwidth | 3 kHz, 30 kHz, 300 kHz, and 5 MHz (-6 dB bandwidth)}}
{{Spec | RF Input impedance | 50 Ω }}
{{Spec | RF Input impedance | 50 Ω }}
{{Spec | Maximum Safe Input Power | +20 dBm (0.1 W or 2.2 V) continuous peak, ≤100 V DC blocking capacitor }}
{{Spec | Maximum Safe Input Power | +20 dBm (0.1 W or 2.2 V) continuous peak, ≤100 V DC blocking capacitor }}
{{Spec | RF Attenuator Range | 0 dB to 50 dB, 2 dB steps }}
{{Spec | RF Attenuator | 0 dB to 50 dB, 2 dB steps }}
{{Spec | Sensitivity | -117 dBm at 3 kHz RBW, -129 dBm at 3 kHz RBW w/preamp }}
{{Spec | Sensitivity | -117 dBm at 3 kHz RBW, -129 dBm at 3 kHz RBW w/preamp }}
{{Spec | Reference Level Range | -70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV }}
{{Spec | Reference Level | -70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV }}
{{Spec | Sweep Speed Range | 2 sec/Div to 1 µs/Div in 1, 2, 5 sequence }}
{{Spec | Sweep Speed | 2 sec/Div to 1 µs/Div in 1, 2, 5 sequence }}
{{Spec | Triggering Modes | Free Run, Internal, External, Line, TV Line, TV Field, single sweep, manual scan }}
{{Spec | Triggering Modes | Free Run, Internal, External, Line, TV Line, TV Field, single sweep, manual scan }}
{{Spec | Displayed Average Noise | −66 dBm to −100 dBm }}
{{Spec | Displayed Average Noise | −66 dBm to −100 dBm }}
Line 39: Line 40:
{{Spec | Dynamic Range | ≥100 dBm }}
{{Spec | Dynamic Range | ≥100 dBm }}
{{Spec | Internal Calibrator | 100 MHz marker at -30 dBm }}
{{Spec | Internal Calibrator | 100 MHz marker at -30 dBm }}
{{Spec | Included Accessories | Operator’s Manual; Power Cord; Front Cover; Adapter 50 Ω N Male to BNC Female }}
{{Spec | Weight | Standard accessories: 9.5 kg (<21 lbs) }}
{{Spec | Weight | Standard accessories: 9.5 kg (<21 lbs) }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 48 to 440 Hz; 90 – 250 V<sub>AC</sub>, 48 to 63 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 90 W (standard), 105 W max (with options) }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 48 to 440 Hz; 90 – 250 V<sub>AC</sub>, 48 to 63 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 90 W (standard), 105 W max (with options) }}
{{Spec | Operating Atmospherics | Temperatures: 0 °C to +50 °C;  Humidity: MIL-T-28800E; Altitude: Up to 4.6 km (15,000 ft) }}
{{EndSpecs}}
{{EndSpecs}}


Line 72: Line 71:
</gallery>
</gallery>


[[Category: Spectrum Analyzers]]
[[Category:Spectrum analyzers]]

Latest revision as of 07:48, 15 October 2022

Tektronix 2711
1.8 GHz Spectrum Analyzer
Tektronix 2711

Produced from 1993 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 2711 is a spectrum analyzer with a frequency range of 9 kHz to 1.8 GHz. The minimum resolution bandwidth is 3 kHz, and provides measurement resolution proportional to the frequency accuracy or span. With non-volatile memory (NVRAM) at 28 kB can save up to 18* displays of waveforms and markers, and up to 9* front panel setups, large user-defined key programs, and antenna factor tables. * Opt. 03 adds additional NVRAM bringing saved displays to 108, and 36 front panel setups.

The single and delta markers provide direct readout of frequency and amplitude information of any point along any displayed trace. Or, get the relative (delta) frequency and amplitude information between any two points along any displayed trace or between traces.

True analog display capability, along with fast sweep speeds and TV Line and TV Field triggering provide demodulation of video carriers for making depth-of-modulation checks or looking at special baseband data, VITS, and other signals. An internal audio amplifier and AM/FM detectors let one hear demodulated signals, using either the build-in speaker or headphone jack for signal identification and troubleshooting and in communications applications.

Additional features include Digital Storage Display (selectable acquisition modes of positive peak only, positive/negative peak, Max hold, Waterfall, and an analog sweep when digital storage is off), Ensemble Averaging, Internal Preamp, Internal Calibrator (accessed through Input Menu), Alternate Reference Level Units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m), User-Definable Power-on Status, Center Measure, Graticule Illumination (for CRT photography), and Direct Plot/Print (Printers via Opt. 03 GPIB, or RS-232-C interface via Opt. 08).

Front panel inputs/outputs are: RF INPUT N connector (50Ω, +20 dBm Max, 100 V DC blocking capacitor); and GEN N connector (50Ω, 0 to -48 dBm, Opt. 4 Tracking Generator generates a sweep frequency to enable the Spectrum Analyzer to make circuit response measurements, i.e. scalar network analysis).

Rear panel inputs/outputs are: J101 SMA connector (Female SMA installed for Opt. 15), J102 EXT TRIG BNC connector (10 kΩ, 50V (DC + peak AC)), J103 DB9 connector (Not RS-232 compatible. Accessory connector: Pin 1 Video Input, Pin 2 Ground, Pin 3 Video Output, Pin 6 Sweep Gate, Pin 7 Sweep Output, all others unused), J104 Opt. 03 GPIB connector (IEEE Std 488 connector) or Opt. 08: RS-232 interface (Digital Communication Port.).

Key Specifications

Frequency 9 kHz to 1.8 GHz
Frequency Span 10 kHz/div to 100 MHz/div in 1, 2, 5 sequence (plus 0 Hz and MAX: 180 MHz/div)
Resolution Bandwidth 3 kHz, 30 kHz, 300 kHz, and 5 MHz (-6 dB bandwidth)
RF Input impedance 50 Ω
Maximum Safe Input Power +20 dBm (0.1 W or 2.2 V) continuous peak, ≤100 V DC blocking capacitor
RF Attenuator 0 dB to 50 dB, 2 dB steps
Sensitivity -117 dBm at 3 kHz RBW, -129 dBm at 3 kHz RBW w/preamp
Reference Level -70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV
Sweep Speed 2 sec/Div to 1 µs/Div in 1, 2, 5 sequence
Triggering Modes Free Run, Internal, External, Line, TV Line, TV Field, single sweep, manual scan
Displayed Average Noise −66 dBm to −100 dBm
Display Dynamic Range 80 dB
Dynamic Range ≥100 dBm
Internal Calibrator 100 MHz marker at -30 dBm
Weight Standard accessories: 9.5 kg (<21 lbs)
Power 90 − 132 VAC, 48 to 440 Hz; 90 – 250 VAC, 48 to 63 Hz. At 115 VAC, 60 Hz, 90 W (standard), 105 W max (with options)

Options

  • Opt. 02: Frequency Counter, 1 Hz or 1 kHz, menu selectable, required to display center frequency and amplitude
  • Opt. 03: GPIB Interface; additional NVRAM and Real-time Clock (cannot be combined with Opt. 08)
  • Opt. 04: TG Tracking Generator, 100 kHz to 1.8 GHz (cannot be combined with Opt. 05)
  • Opt. 05: External Tracking Generator with Active Probe Power Jack (not compatible with Opt. 04)
  • Opt. 07: Add 2704 Inverter/2705 Battery Pack.
  • Opt. 10: Video Monitor mode
  • Opt. 15: Tek 1405 TV Sideband Adapter interface installed at J101 as SMA female
  • Opt. 20: EMC antenna set plus tripod and coax suitable for tests to 1 GHz
  • Opt. 21: Add 2706 Stepping RF Preselector
  • Opt. 30: Rackmount
  • Opt. 33: Travel Line Package
  • Opt. 34: Portable to Rackmount Adapter.

See also the 2706 preselector and 2707 tracking generator.