{{Oscilloscope Sidebar |
{{Instrument Sidebar
title=Tektronix RSA3308B |
|class=Spectrum Analyzer
summary=Spectrum Analyzer DC to 8 GHz |
|manufacturer=Tektronix  
image= RSA3303B_1.jpg |
|model=RSA3308B
caption=Tektronix RSA3308B |
|summary=8 GHz Spectrum Analyzer
introduced=(?) |
|image= RSA3303B_1.jpg
discontinued=(?) |
|caption=Tektronix RSA3308B
manuals=
|introduced=(?)
* [[Media: 37W_23236_6_0_RSA3000B Series Data Sheet.pdf | 37W_23236_6 RSA3000B Datasheet (PDF, OCR)]]
|discontinued=(?)
* [[Media: 071-2395-00_RSA3303B, RSA3308B, and RSA3408B User Manual.pdf | 071-2395-00 RSA3303B, RSA3308B, and RSA3408B User Manual (PDF, OCR)]]
|manuals=
* [[Media:071-2367-01_RSA3303B and RSA3308B Service Manual.pdf | 071-2367-01 RSA3303B and RSA3308B Service Manual (PDF, OCR)]]
* [[Media:37W_23236_6.pdf|RSA3000B Datasheet]] (OCR)
* [[Media: 075-1028-00 RSA3000B 119-7548-XX CPU Card Assembly Replacement Instructions.pdf | 075-1028-00 RSA3000B 119-7548-XX CPU Card Assembly Replacement Instructions (PDF, OCR)]]
* [[Media:071-2395-00.pdf|RSA3303B, RSA3308B, and RSA3408B User Manual]] (OCR)
* [[Media: 077-0111-00_RSA3303B, RSA3308B, & RSA3408B Programmer Manual.pdf | 077-0111-00 RSA3303B, RSA3308B, & RSA3408B Programmer Manual (PDF, OCR)]]
* [[Media:071-2367-01.pdf|RSA3303B and RSA3308B Service Manual]] (OCR)
* [[Media:075-1028-00.pdf|RSA3000B 119-7548-XX CPU Card Assembly Replacement Instructions]] (OCR)
* [[Media:077-0111-00.pdf|RSA3303B, RSA3308B, & RSA3408B Programmer Manual]] (OCR)
}}
}}
The '''RSA3308B''' is a portable Real-time Spectrum Analyzer (RSA) meant for lab or production line use with a frequency range of DC to 8 GHz is capable of capturing continuous, intermittent, or random signals.  With Digital phosphor spectrum processing (DPX) this RSA provides the user the ability to view time-varying RF signals with color-graded displays based on frequency.  For offline spectral analysis users can install the [[RSAVu]] Real-Time Spectrum Analyzer Software on their PC and offload  '''.iqt''' and '''.tiq''' waveform data files to it.
The '''RSA3308B''' is a portable Real-time Spectrum Analyzer (RSA) meant for lab or production line use with a frequency range of DC to 8 GHz is capable of capturing continuous, intermittent, or random signals.  With Digital phosphor spectrum processing (DPX) this RSA provides the user the ability to view time-varying RF signals with color-graded displays based on frequency.  For offline spectral analysis users can install the [[RSAVu]] Real-Time Spectrum Analyzer Software on their PC and offload  '''.iqt''' and '''.tiq''' waveform data files to it.


Line 22: Line 23:
Front panel inputs/outputs are: RF IN [[N connector]] (50Ω, +30 dBm max); PreAmp Pwr [[LEMO S-series connector]] (Preamp power connector).
Front panel inputs/outputs are: RF IN [[N connector]] (50Ω, +30 dBm max); PreAmp Pwr [[LEMO S-series connector]] (Preamp power connector).


Rear panel inputs/outputs: REF OUT/IN [[BNC connector]]s (50Ω); I+/I- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); Q+/Q- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); TRIG OUT/IN [[BNC connector]]s (50Ω); GPIB [[GPIB connector]] (); and US Power Plug (115 V nominal) .
Rear panel inputs/outputs: REF OUT/IN [[BNC connector]]s (50Ω); I+/I- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); Q+/Q- INPUT [[BNC connector]]s (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); TRIG OUT/IN [[BNC connector]]s (50Ω); [[GPIB connector]] (IEEE 488.2); and US Power Plug (115 V nominal).


Side panel inputs/outputs:  LAN [[Ethernet]] connector (10/100BASE-T), [[VGA Connector]], and 2 X [[USB connector]]s (USB 1.1).
Side panel inputs/outputs:  LAN [[Ethernet]] connector (10/100BASE-T), [[VGA Connector]], and 2 X [[USB connector]]s (USB 1.1).
Line 33: Line 34:
{{Spec | Input RF/Baseband Attenuator | 0 dB to 50 dB (2 dB step at <3.5 GHz, 10 dB step at ≥3.5 GHz) }}  
{{Spec | Input RF/Baseband Attenuator | 0 dB to 50 dB (2 dB step at <3.5 GHz, 10 dB step at ≥3.5 GHz) }}  
{{Spec | Input IQ Input Attenuator | 0 dB to 30 dB (10 dB step) }}   
{{Spec | Input IQ Input Attenuator | 0 dB to 30 dB (10 dB step) }}   
{{Spec | Dynamic Range (Spurious Free) | -70 dBc/15 MHz }}   
{{Spec | Dynamic Range (Spurious Free) | –70 dBc/15 MHz }}   
{{Spec | Reference Level Range | -50 dBm to +30 dBm (1 dB step) (RF); -30 dBm to +20 dBm (5 dB step) (Baseband); -10 dBm to +20 dBm (5 dB step) (IQ Inputs) }}
{{Spec | Reference Level Range | –50 dBm to +30 dBm (1 dB step) (RF); –30 dBm to +20 dBm (5 dB step) (Baseband); –10 dBm to +20 dBm (5 dB step) (IQ Inputs) }}
{{Spec | Resolution Bandwidth per Span (1 Hz to 10 MHz) | Span > 2 GHz: 100 kHz min; to Span 100 Hz: 1 Hz min }}  
{{Spec | Resolution Bandwidth per Span (1 Hz to 10 MHz) | Span > 2 GHz: 100 kHz min; to Span 100 Hz: 1 Hz min }}  
{{Spec | IQ Inputs (Opt 03) | 20 MHz BW Differential }}  
{{Spec | IQ Inputs (Opt 03) | 20 MHz BW Differential }}  
{{Spec | Minimum Signal Duration for 100% POI | ≤41 µsec }}  
{{Spec | Minimum Signal Duration for 100% POI | ≤41 µsec }}  
{{Spec | Trigger Types | Level, Free run, External, and Freq. Mask Trigger (Opt. 02) }}
{{Spec | Trigger Types | Level, Free run, External, and Freq. Mask Trigger (Opt. 02) }}
{{Spec | Ext Trigger Threshold Levels | -1.5 to +1.5 V settable }}
{{Spec | Ext Trigger Threshold Levels | –1.5 to +1.5 V settable }}
{{Spec | Displayed Average Noise at 1 GHz (Preamp off) | −150 dBm/Hz }}  
{{Spec | Displayed Average Noise at 1 GHz (Preamp off) | −150 dBm/Hz }}  
{{Spec | Phase Noise at offsets from 1 GHz (dBc/Hz) | 10 kHz: -108, 1 MHz: -133, 10 MHz: -136 }}   
{{Spec | Phase Noise at offsets from 1 GHz (dBc/Hz) | 10 kHz: –108, 1 MHz: –133, 10 MHz: –136 }}   
{{Spec | Included Accessories | User Manual, Programmer’s Manual (on CD), Power cord, BNC to N Adapter, USB keyboard, USB mouse, and Front Cover }}
{{Spec | Weight (all options) | 20 kg (44 lbs) }}  
{{Spec | Weight (all options) | 20 kg (44 lbs) }}  
{{Spec | Power & Dissipation (fully loaded) | 90 - 250 V, 47 to 63 Hz, 350 W max; the principal power switch in at the lower left corner of the rear panel, while the front panel power switch allows ON  or STANDBY modes }}
{{Spec | Power & Dissipation (fully loaded) | 90 250 V, 47 to 63 Hz, 350 W max; the principal power switch in at the lower left corner of the rear panel, while the front panel power switch allows ON  or STANDBY modes }}
{{Spec | Operating Atmospherics | Temperatures: +10 °C to +40 °C; Humidity: 20% to 80% (no condensation); Altitude: Up to 3000 m (9842 ft) }}
{{EndSpecs}}
{{EndSpecs}}


Line 57: Line 56:
* Opt. C3: Calibration Service 3 Years
* Opt. C3: Calibration Service 3 Years
* Opt. C5: Calibration Service 5 Years
* Opt. C5: Calibration Service 5 Years
* Opt. CA1: Single Calibration or Functional Verification
* Opt. D1: Calibration Data Report
* Opt. D1: Calibration Data Report
* Opt. D3: Calibration Data Report 3 Years (with Opt. C3)
* Opt. D3: Calibration Data Report 3 Years (with Opt. C3)
Line 71: Line 69:
</gallery>
</gallery>


[[Category: Spectrum Analyzers]]
[[Category:Spectrum analyzers]]

Latest revision as of 09:29, 13 October 2022

Tektronix RSA3308B
8 GHz Spectrum Analyzer
Tektronix RSA3308B

Produced from (?) to (?)

Manuals
Manuals – Specifications – Links – Pictures

The RSA3308B is a portable Real-time Spectrum Analyzer (RSA) meant for lab or production line use with a frequency range of DC to 8 GHz is capable of capturing continuous, intermittent, or random signals. With Digital phosphor spectrum processing (DPX) this RSA provides the user the ability to view time-varying RF signals with color-graded displays based on frequency. For offline spectral analysis users can install the RSAVu Real-Time Spectrum Analyzer Software on their PC and offload .iqt and .tiq waveform data files to it.

The RSA’s has a 8.4 inch TFT color display, a 20 GB hard drive, and a diskette drive (either a 3.5-inch 2HD (1.44 MB) or 2DD (720 KB)) to save and load data and settings.

This RSA is capable of performing spectrum analysis of power, ACPR, C/N, OBW, EBW, and spurious signals. Analog modulation analysis is possible with AM, PM, FM, ASK, and FSK signals. Additionally, this RSA can perform digital modulation analysis from BPSK to 256QAM (with option 21 of the RSAVu software), time characteristics analysis including pulse measurements, constellation analysis, EVM analysis, AM/AM and AM/PM distortion analysis, RFID analysis, signal source analysis, and CCDF analysis.

Front panel inputs/outputs are: RF IN N connector (50Ω, +30 dBm max); PreAmp Pwr LEMO S-series connector (Preamp power connector).

Rear panel inputs/outputs: REF OUT/IN BNC connectors (50Ω); I+/I- INPUT BNC connectors (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); Q+/Q- INPUT BNC connectors (50Ω, when using one connector as a single-ended input terminate the other end in 50Ω, Opt. 03 only); TRIG OUT/IN BNC connectors (50Ω); GPIB connector (IEEE 488.2); and US Power Plug (115 V nominal).

Side panel inputs/outputs: LAN Ethernet connector (10/100BASE-T), VGA Connector, and 2 X USB connectors (USB 1.1).

Key Specifications

Frequency Range DC to 8 GHz
Max Capture BW 15 MHz
RF Input impedance 50 Ω
Maximum Safe RF Input Power +30 dBm ±0.2 V (RF Band) ±5 V (Baseband) ±5 V (IQ input), RF Attn ≥10 dB
Input RF/Baseband Attenuator 0 dB to 50 dB (2 dB step at <3.5 GHz, 10 dB step at ≥3.5 GHz)
Input IQ Input Attenuator 0 dB to 30 dB (10 dB step)
Dynamic Range (Spurious Free) –70 dBc/15 MHz
Reference Level Range –50 dBm to +30 dBm (1 dB step) (RF); –30 dBm to +20 dBm (5 dB step) (Baseband); –10 dBm to +20 dBm (5 dB step) (IQ Inputs)
Resolution Bandwidth per Span (1 Hz to 10 MHz) Span > 2 GHz: 100 kHz min; to Span 100 Hz: 1 Hz min
IQ Inputs (Opt 03) 20 MHz BW Differential
Minimum Signal Duration for 100% POI ≤41 µsec
Trigger Types Level, Free run, External, and Freq. Mask Trigger (Opt. 02)
Ext Trigger Threshold Levels –1.5 to +1.5 V settable
Displayed Average Noise at 1 GHz (Preamp off) −150 dBm/Hz
Phase Noise at offsets from 1 GHz (dBc/Hz) 10 kHz: –108, 1 MHz: –133, 10 MHz: –136
Weight (all options) 20 kg (44 lbs)
Power & Dissipation (fully loaded) 90 – 250 V, 47 to 63 Hz, 350 W max; the principal power switch in at the lower left corner of the rear panel, while the front panel power switch allows ON or STANDBY modes

Options (specific to RSA – Not RSAVu software)

  • Opt. 02: 65.5 MSample Deep Memory, Frequency Mask Trigger
  • Opt. 03: IQ, Differential IQ inputs
  • Opt. 28: TD-SCDMA Analysis

Service Options

  • Opt. CA1: Single Calibration or Functional Verification
  • Opt. C3: Calibration Service 3 Years
  • Opt. C5: Calibration Service 5 Years
  • Opt. D1: Calibration Data Report
  • Opt. D3: Calibration Data Report 3 Years (with Opt. C3)
  • Opt. D5: Calibration Data Report 5 Years (with Opt. C5)
  • Opt. G3: Complete Care 3 Years (includes loaner, scheduled calibration, and more)
  • Opt. G5: Complete Care 5 Years (includes loaner, scheduled calibration, and more)
  • Opt. R5: Repair Service 5 Years (including warranty)

Pictures