[[Image:Ths720std-comp.jpg|thumb|400px|right|Tektronix THS720 Std probe compensation]]
{{Oscilloscope Sidebar
|manufacturer=Tektronix
|series=THS series scopes
|model=THS720
|summary=100 MHz 2-ch portable digital scope
|image=Ths720std-comp.jpg
|caption=Tektronix THS720
|introduced=(?)
|discontinued=(?)
|designers=Murlan Kaufman;
|manuals=
'''THS710, 720'''
* [[Media:070-9245-00.pdf|Programmer Manual 070-9245-00]]
* [[Media:070-9246-03.pdf|Service Manual 070-9246-03]]
* [[Media:070-9247-02.pdf|User Manual 070-9247-02]]
* [[Media:070-9257-00.pdf|Reference Manual 070-9257-00]]


'''THS710A, 720A, 720P, 730A'''
* [[Media:061-4241-01.pdf|THS720A, 720P, 730A Release Notes 061-4241-01]]
* [[Media:070-9731-05.pdf|User Manual 070-9731-05]]<br/><small>  Other versions: [[Media:070-9731-03.pdf|-03]] / [[Media:070-9752-01.pdf|-01]]</small>
* [[Media:070-9740-05.pdf|Japanese User Manual 070-9740-05]]
* [[Media:070-9741-01.pdf|Reference Manual 070-9741-01]]<br/><small>  Other versions: [[Media:070-9741-00.pdf|-00]]</small>
* [[Media:070-9751-01.pdf|Programmer Manual 070-9751-01]]
* [[Media:070-9752-02.pdf|Service Manual 070-9752-02]]<br/><small>  Other versions: [[Media:070-9752-01.pdf|-01]] / [[Media:070-9752-00.pdf|-00]]</small>
'''Other'''
* [[Media:061-4241-00.pdf|THS720A, THS720P, THS730A Release Notes 061-4241-00]]
* [[Media:061-4241-01.pdf|THS720A, THS720P, THS730A Release Notes 061-4241-01]]
* [[Media:070-9309-04.pdf|THS7CHG Instructions 070-9309-04]]
* [[Media:070-9750-02.pdf|THS720A MOD NV TekScope Component-Level Information Package 070-9750-02]]
* [[Media:THS7XXAPDiag.pdf|THS700 Schematics]]
* [[Media:070-9785-03.pdf|WaveStar Software User Manual 070-9785-03]]
* [[Media:071-1815-00.pdf|Memory Erasure and Memory Parts List 071-1815-00]]
* [[Media:3MW-10566-6.pdf|Tektronix THS700 Series Product Brochure (2006)]]
==Firmware==
* [[Media:THS720_v1.03_Firmware.zip|THS720STD v1.03 Firmware]] (ZIP)
* [[Media:THS710A_v1.11_Firmware.zip|THS710A v1.11 Firmware]] (ZIP)
* [[Media:THS720x_v1.16_Firmware.zip|THS720A, THS720P v1.16 Firmware]] (ZIP)
}}
The '''Tektronix THS720''' is a portable 100 MHz, 500 MS/s (each channel) dual-channel digital oscilloscope with isolated inputs.
The '''Tektronix THS720''' is a portable 100 MHz, 500 MS/s (each channel) dual-channel digital oscilloscope with isolated inputs.
There were two variants, the THS720 STD and the THS720A.   
 
The primary difference is that the THS720A will trigger from the DMM input.
There were two variants, the THS720 STD and the THS720A.  The primary difference is that the THS720A will trigger from the DMM input.
 
The '''THS720P''' includes features for electrical/power electronics measurements.
 
[[Murlan Kaufman]] designed the THS700 series high voltage isolated front end.


{{MissingSpecs}}
{{MissingSpecs}}
See [[THS720/Accessories]] for details on cables and other accessories.


==Operation==
==Operation==


Due to the isolated inputs, the probe ground must be connected even when
Due to the isolated inputs, the probe ground must be connected even when compensating the probes with the "PROBE COMP" output.   
compensating the probes with the "PROBE COMP" output.  It can be used with
It can be used with any BNC probe but the scale factor pin found on many Tektronix probes is not used.   
any BNC probe but the scale factor pin found on many Tektronix probes is
The vertical menu has a scale factor entry (1×, 10×, 100×, 1000×) which can also be used for direct BNC inputs.
not used.  The vertical menu has a scale factor entry (1×, 10×, 100×, 1000×)
which can also be used for direct BNC inputs.


Recommended probes are the [[P5102]] and the [[P6113B]], both are 10× probes
Recommended probes are the [[P5102]] and the [[P6113B]], both are 10× probes with protected grounds for isolated measurements.   
with protected grounds for isolated measurements.  The [[P5102]] has the best
The [[P5102]] has the best isolation, allowing 600 V between reference ground and earth ground.
isolation, allowing 600V between reference ground and earth ground.
 
==Links==
* [https://www.eevblog.com/forum/testgear/tek-ths720a-portable-scope-teardowndiscussion// EEVBlog Forum thread on The THS7XXX series scopes]
* [https://www.youtube.com/watch?v=ajKtOf3kfuw Tektronix THS700 Series Oscilloscope Mega Video] by Near Far Media @ YouTube
{{Documents|Link=THS720}}
{{PatentLinks|THS720}}


==Internals==
==Internals==
Line 26: Line 73:
The DMM is a 3¾-digit Maxim MAX134CQH.
The DMM is a 3¾-digit Maxim MAX134CQH.


The analog scope section starts with an attenuator hybrid driven by four channels of
The analog scope section starts with an attenuator hybrid driven by four channels of HP (now Broadcom/Avago) optoisolators and NEC relays.   
HP (now Avago) optoisolators and NEC relays.  The hybrid contains the AC coupling
The hybrid contains the AC coupling capacitor and many laser trimmed resistors along with a custom Tek chip ([[165-2545-00]]) in a BGA package.
capacitor and many laser trimmed resistors along with a custom Tek [[165-2545-00]] BGA.
The signal then passes through a single-ended to differential transformer and goes to a custom-labeled Maxim two-channel high speed A/D converter ([[234-1503-20]]).
The signal then passes through a single-ended to differential transformer and
Note that the differential signal layout for channel 2 is not as good as channel 1 since one side of channel 2 goes through 2 vias not found on channel 1.
goes to a custom labeled Maxim two-channel high speed A/D converter [[234-1503-20]].
These optoisolators sometimes drift, causing a DC offset issue. They can be directly replaced with Broadcom/Avago part number HCNR201 (any of the -300E, -500E, -350E, or -550E variants will work) which are still readily available.
Note that the differential signal layout for channel 2 is not as good as channel 1
since one side of channel 2 goes through 2 vias not found on channel 1.


==Repair Issues==
Firmware is updated using the [[067-1436-00|067-1436-00 Communication Pod]] with an adapter cable via an internal connector.


The service manual shows how to remove the calibration protection jumper.
A THS710A and THS720A can be upgraded to a THS720P with the removal of a few resistors on the main board (see pictures for details). No adjustment/calibration is required after this modification.
The DMM calibration step requires a good calibrator capable of doing 850 V<sub>DC</sub>
and 600 V<sub>AC</sub> at 500 Hz.  Scope calibration is much simpler requiring only a
square wave pulser and a DC voltage source.  Note that after a cal fail, there
is an error log in a nearby menu indexed by power on count.


When confronted by scope calibration failures that say "Cal error, DC balance"
NOTE: A THS710STD can be upgraded to a THS720STD, but due to main board differences, these models CANNOT be upgraded to a -A or -P model<br>
and there are persistent DC offsets that increase with the attenuator settings
Additionally, lower model scopes cannot be upgraded to a THS730A due to different input hybrid modules being used in the THS730A to provide the increased bandwidth.
try replacing U45 and U46.  They are HP CNR201A analog optoisolators, now made
by Avago as the HCNR201-300E.  They send a low pass filtered version of the
input signal across the isolation barrier to give the DC levels that can not
cross the high frequency transformer isolation barrier.


The battery pack is, of course, custom. It appears to be 4 C cell NiCd pack
==Software==
with the positive terminal moved to a ring around the bottom (most negative) cell.
* [[Media:066-0109-00.zip|DOS program to display FFT - 066-0109-00]] (ZIP)
If you are not concerned with interchanging packs or using the separate charger, the
* [[Media:066-0153-00.zip|THS General Extended Logging Feature Software - 066-0153-00]] (ZIP, 48 KB)
cells can simply be soldered into the lower housing.
* [[Media:Wintek32.zip|Wintek32 THS General BMP Extractor v2.0.5.21]] <small> Other versions: [[Media:066-0154-00.zip|066-0154-00 v2.01]] (ZIP, 90 KB)</small>
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03]] (ZIP, 102MB) ''Product Key: WSTRO618650124''
* [[Media:Docuwave_1.2.zip|Docuwave 1.2 for DOS]] (ZIP, 704 KB)
* [[Media:THS7XX_v1.3.zip|THS7XX HardCopy by Marco M. Schäck]] (ZIP, 63KB) [https://www.schaeck-online.de/download/?dir=THS7XX%20HardCopy www.schaeck-online.de]


See [[THS700]] for the manuals.
==Pictures==
'''THS720'''
<gallery>
ths720std-comp.jpg|THS720STD Displaying probe compensation waveform
THS720STD_PCB_Top.jpg|THS720STD Top of Main PCB
<!-- ths720std-mcudmm.JPG|THS720STD main board MCU and DMM -->
<!-- ths720std-powerbnc.JPG|THS720 STD main board BNC inputs and power supply -->
THS720STD_PCB_Bottom.jpg|THS720STD Back of Main PCB
ths720std-attenuator.JPG|THS720STD Attenuator with cover removed
<!-- ths720std-scopeanalog.JPG|THS720STD Analog scope section -->
ths720std-runningboard.jpg|THS720STD Operation without case
</gallery>


==Pictures==
'''THS720A'''
<gallery>
Tek ths720a 1.jpg
Tek ths720a 2.jpg
Tek ths720a 3.jpg
Tek ths720a 4.jpg
Tek ths720a 5.jpg
Tek ths720a 6.jpg
Tek ths720a 7.jpg
Tek ths720a 8.jpg
Tektronix_THS720A_to_720P_Hack.jpg|THS720P Upgrade mod
</gallery>
 
'''THS720P'''
<gallery>
ths720p.jpg
THS720P_PCB_Top.jpg|THS720P Top of Main PCB
THS720P_PCB_Bottom.jpg|THS720P Back of Main PCB
</gallery>
 
'''Accessories'''
<gallery>
<gallery>
ths720std-comp.jpg|THS720 Std displaying probe compensation waveform
THS7CHG.jpg|Battery Charger
ths720std-toppcb.JPG|THS720 std top of main PCB
THS7CHG_Internal.jpg|Battery Charger Internal
ths720std-mcudmm.JPG|THS720 std main board MCU and DMM
ths720std-powerbnc.JPG|THS720 std main board BNC inputs and power supply
ths720std-backpcb.jpg|THS720 std back of main PCB
ths720std-attenuator.JPG|THS720 std attenuator with cover removed
ths720std-scopeanalog.JPG|THS720 std analog scope section
ths720std-runningboard.jpg|THS720 std operation without case
Tek ths720a 1.jpg|THS720A
Tek ths720a 2.jpg|THS720A
Tek ths720a 3.jpg|THS720A
Tek ths720a 4.jpg|THS720A
Tek ths720a 5.jpg|THS720A
Tek ths720a 6.jpg|THS720A
Tek ths720a 7.jpg|THS720A
Tek ths720a 8.jpg|THS720A
</gallery>
</gallery>
==Components==
{{Parts|THS720}}


[[Category:THS series scopes]]
[[Category:THS series scopes]]

Latest revision as of 05:46, 16 October 2024

Manuals – Specifications – Links – Pictures

The Tektronix THS720 is a portable 100 MHz, 500 MS/s (each channel) dual-channel digital oscilloscope with isolated inputs.

There were two variants, the THS720 STD and the THS720A. The primary difference is that the THS720A will trigger from the DMM input.

The THS720P includes features for electrical/power electronics measurements.

Murlan Kaufman designed the THS700 series high voltage isolated front end.

Key Specifications

  • please add

See THS720/Accessories for details on cables and other accessories.

Operation

Due to the isolated inputs, the probe ground must be connected even when compensating the probes with the "PROBE COMP" output. It can be used with any BNC probe but the scale factor pin found on many Tektronix probes is not used. The vertical menu has a scale factor entry (1×, 10×, 100×, 1000×) which can also be used for direct BNC inputs.

Recommended probes are the P5102 and the P6113B, both are 10× probes with protected grounds for isolated measurements. The P5102 has the best isolation, allowing 600 V between reference ground and earth ground.

Links

Documents Referencing THS720

(no results)

Internals

Primary microprocessor is the Motorola/Freescale MC68331CFC16. An Intel E28F008SA120 Flash Memory chip is used for setup, cal and waveform storage. The switching power supply is run by a TL1451A, a TI two channel boost/buck controller. The DMM is a 3¾-digit Maxim MAX134CQH.

The analog scope section starts with an attenuator hybrid driven by four channels of HP (now Broadcom/Avago) optoisolators and NEC relays. The hybrid contains the AC coupling capacitor and many laser trimmed resistors along with a custom Tek chip (165-2545-00) in a BGA package. The signal then passes through a single-ended to differential transformer and goes to a custom-labeled Maxim two-channel high speed A/D converter (234-1503-20). Note that the differential signal layout for channel 2 is not as good as channel 1 since one side of channel 2 goes through 2 vias not found on channel 1. These optoisolators sometimes drift, causing a DC offset issue. They can be directly replaced with Broadcom/Avago part number HCNR201 (any of the -300E, -500E, -350E, or -550E variants will work) which are still readily available.

Firmware is updated using the 067-1436-00 Communication Pod with an adapter cable via an internal connector.

A THS710A and THS720A can be upgraded to a THS720P with the removal of a few resistors on the main board (see pictures for details). No adjustment/calibration is required after this modification.

NOTE: A THS710STD can be upgraded to a THS720STD, but due to main board differences, these models CANNOT be upgraded to a -A or -P model
Additionally, lower model scopes cannot be upgraded to a THS730A due to different input hybrid modules being used in the THS730A to provide the increased bandwidth.

Software

Pictures

THS720

THS720A

THS720P

Accessories

Components

Some Parts Used in the THS720

Part Part Number(s) Class Description Used in
Motorola 68000 156-1445-00 Monolithic integrated circuit 16-bit microprocessor 4041 AM700 DAS9200 Keithley 182 RTD710 SG5030 Prism 3002 THS720